Monte Carlo simulation of the basic features of the GE Millennium MG single photon emission computed tomography gamma camera.

作者信息

Vieira L, Vaz T F, Costa D C, Almeida P

机构信息

Instituto de Biofísica e Engenharia Biomédica, Faculdade de Ciências, Universidade de Lisboa, Lisboa, Portugal; Área Científica de Medicina Nuclear, Escola Superior de Tecnologia da Saúde de Lisboa, Instituto Politécnico de Lisboa, Lisboa, Portugal.

Área Científica de Medicina Nuclear, Escola Superior de Tecnologia da Saúde de Lisboa, Instituto Politécnico de Lisboa, Lisboa, Portugal.

出版信息

Rev Esp Med Nucl Imagen Mol. 2014 Jan-Feb;33(1):6-13. doi: 10.1016/j.remn.2013.03.009. Epub 2013 May 30.

Abstract

OBJECTIVE

To describe and validate the simulation of the basic features of GE Millennium MG gamma camera using the GATE Monte Carlo platform.

MATERIAL AND METHODS

Crystal size and thickness, parallel-hole collimation and a realistic energy acquisition window were simulated in the GATE platform. GATE results were compared to experimental data in the following imaging conditions: a point source of (99m)Tc at different positions during static imaging and tomographic acquisitions using two different energy windows. The accuracy between the events expected and detected by simulation was obtained with the Mann-Whitney-Wilcoxon test. Comparisons were made regarding the measurement of sensitivity and spatial resolution, static and tomographic. Simulated and experimental spatial resolutions for tomographic data were compared with the Kruskal-Wallis test to assess simulation accuracy for this parameter.

RESULTS

There was good agreement between simulated and experimental data. The number of decays expected when compared with the number of decays registered, showed small deviation (≤ 0.007%). The sensitivity comparisons between static acquisitions for different distances from source to collimator (1, 5, 10, 20, 30 cm) with energy windows of 126-154 keV and 130-158 keV showed differences of 4.4%, 5.5%, 4.2%, 5.5%, 4.5% and 5.4%, 6.3%, 6.3%, 5.8%, 5.3%, respectively. For the tomographic acquisitions, the mean differences were 7.5% and 9.8% for the energy window 126-154 keV and 130-158 keV. Comparison of simulated and experimental spatial resolutions for tomographic data showed no statistically significant differences with 95% confidence interval.

CONCLUSIONS

Adequate simulation of the system basic features using GATE Monte Carlo simulation platform was achieved and validated.

摘要

目的

使用GATE蒙特卡罗平台描述并验证通用电气公司千年MG型γ相机基本特征的模拟情况。

材料与方法

在GATE平台中模拟晶体尺寸和厚度、平行孔准直以及实际的能量采集窗口。将GATE模拟结果与以下成像条件下的实验数据进行比较:在静态成像和断层扫描采集中,使用两个不同能量窗口,位于不同位置的(99m)Tc点源。通过曼-惠特尼-威尔科克森检验获得模拟预期事件与检测到事件之间的准确性。对静态和断层扫描的灵敏度和空间分辨率测量进行了比较。使用克鲁斯卡尔-沃利斯检验比较断层扫描数据的模拟和实验空间分辨率,以评估该参数的模拟准确性。

结果

模拟数据与实验数据之间具有良好的一致性。预期衰变次数与记录的衰变次数相比,偏差较小(≤0.007%)。对于源到准直器不同距离(1、5、10、20、30厘米)的静态采集,能量窗口为126 - 154 keV和130 - 158 keV时,灵敏度比较显示差异分别为4.4%、5.5%、4.2%、5.5%、4.5%和5.4%、6.3%、6.3%、5.8%、5.3%。对于断层扫描采集,能量窗口126 - 154 keV和130 - 158 keV时的平均差异分别为7.5%和9.8%。断层扫描数据的模拟和实验空间分辨率比较显示,在95%置信区间内无统计学显著差异。

结论

使用GATE蒙特卡罗模拟平台对系统基本特征进行了充分的模拟并得到验证。