BACKGROUND

We analyzed the performance of a novel ENA screening chemiluminescent immunoassay (CIA) and the confirmation QUANTA Flash tests.

METHODS

Sera (n=1079) from patients referred to a rheumatology clinic were screened by QUANTA Flash ENA7 (INOVA Diagnostics). All positive (n=89) and a matched control group (n=90) were reflexed for autoantibodies to the individual antigens. Moreover, sera from patients with systemic lupus erythematosus (SLE, n=252), systemic sclerosis (SSc, n=64), polymyositis/dermatomyositis (PM/DM, n=72), Sjögren's syndrome (SjS, n=39) as well as disease controls (n=605) were tested by ENA7 CIA and by Quanta Lite ENA6 ELISA (INOVA).

RESULTS

89/1079 (8.3%) samples were ENA7 CIA positive with the following reactivity profile: RNP (36.0%), Sm (13.5%), Scl-70 (9.0%), Jo-1 (0.0%), Ro60 (44.9%), Ro52 (39.3%) and SS-B (24.7%). In the negative group, the reactivity profile was: RNP (1.1%), Sm (1.1%), Scl-70 (2.2%) and 0.0% for Jo-1, Ro60, Ro52 and SS-B. The positive/negative/total agreements (ENA7 CIA vs. confirmation assays) were 95.3%/91.5%/93.3%. The sensitivity of the ENA7 CIA was 62.3% in SLE, 54.7% in SSc, 92.3% in SjS, 50.0% in PM/DM, and 61.8% in the total systemic autoimmune rheumatic disease (SARD) population (specificity 95.0%).

CONCLUSION

The QUANTA Flash ENA7 CIA is a reliable screening test.

摘要

背景

我们分析了一种新型 ENA 筛选化学发光免疫分析(CIA)和 QUANTA Flash 检测的性能。

方法

对风湿病诊所就诊患者的血清(n=1079)进行 QUANTA Flash ENA7(INOVA Diagnostics)检测。所有阳性(n=89)和匹配的对照组(n=90)均进行针对个别抗原的自身抗体的反射检测。此外,还对系统性红斑狼疮(SLE,n=252)、系统性硬皮病(SSc,n=64)、多发性肌炎/皮肌炎(PM/DM,n=72)、干燥综合征(SjS,n=39)以及疾病对照组(n=605)的血清进行 ENA7 CIA 和 Quanta Lite ENA6 ELISA(INOVA)检测。

结果

89/1079(8.3%)样本 ENA7 CIA 阳性,其反应谱如下:RNP(36.0%)、Sm(13.5%)、Scl-70(9.0%)、Jo-1(0.0%)、Ro60(44.9%)、Ro52(39.3%)和 SS-B(24.7%)。在阴性组中,反应谱为:RNP(1.1%)、Sm(1.1%)、Scl-70(2.2%)和 Jo-1、Ro60、Ro52 和 SS-B 为 0.0%。(ENA7 CIA 与确认检测)的阳性/阴性/总符合率分别为 95.3%/91.5%/93.3%。ENA7 CIA 的灵敏度在 SLE 中为 62.3%,在 SSc 中为 54.7%,在 SjS 中为 92.3%,在 PM/DM 中为 50.0%,在整个系统性自身免疫性风湿病(SARD)人群中为 61.8%(特异性 95.0%)。

结论

QUANTA Flash ENA7 CIA 是一种可靠的筛查试验。