Sudahar H, Kurup P G G, Murali V, Mahadev P, Velmurugan J
Department of Radiotherapy, Apollo Speciality Hospital, Chennai, India.
Med Dosim. 2013 Winter;38(4):385-9. doi: 10.1016/j.meddos.2013.04.006. Epub 2013 Jun 25.
The present study is to analyze the CyberKnife hypofractionated dose distribution of localized prostate cancer in terms of high-dose rate (HDR) brachytherapy equivalent doses to assess the degree of HDR brachytherapy resemblance of CyberKnife dose distribution. Thirteen randomly selected localized prostate cancer cases treated using CyberKnife with a dose regimen of 36.25Gy in 5 fractions were considered. HDR equivalent doses were calculated for 30Gy in 3 fractions of HDR brachytherapy regimen. The D5% of the target in the CyberKnife hypofractionation was 41.57 ± 2.41Gy. The corresponding HDR fractionation (3 fractions) equivalent dose was 32.81 ± 1.86Gy. The mean HDR fractionation equivalent dose, D98%, was 27.93 ± 0.84Gy. The V100% of the prostate target was 95.57% ± 3.47%. The V100% of the bladder and the rectum were 717.16 and 79.6mm(3), respectively. Analysis of the HDR equivalent dose of CyberKnife dose distribution indicates a comparable resemblance to HDR dose distribution in the peripheral target doses (D98% to D80%) reported in the literature. However, there is a substantial difference observed in the core high-dose regions especially in D10% and D5%. The dose fall-off within the OAR is also superior in reported HDR dose distribution than the HDR equivalent doses of CyberKnife.
本研究旨在根据高剂量率(HDR)近距离放射治疗等效剂量,分析射波刀低分次照射局部前列腺癌的剂量分布,以评估射波刀剂量分布与HDR近距离放射治疗的相似程度。研究纳入了13例随机选择的局部前列腺癌病例,这些病例采用射波刀治疗,剂量方案为5次分割,总剂量36.25Gy。计算了HDR近距离放射治疗方案3次分割、总剂量30Gy时的等效剂量。射波刀低分次照射时靶区的D5%为41.57±2.41Gy。相应的HDR分次照射(3次分割)等效剂量为32.81±1.86Gy。平均HDR分次照射等效剂量D98%为27.93±0.84Gy。前列腺靶区的V100%为95.57%±3.47%。膀胱和直肠的V100%分别为717.16和79.6mm³。对射波刀剂量分布的HDR等效剂量分析表明,其在外周靶区剂量(文献报道的D98%至D80%)方面与HDR剂量分布具有相当的相似性。然而,在核心高剂量区域,尤其是D10%和D5%区域,观察到存在显著差异。在正常组织器官内,文献报道的HDR剂量分布的剂量下降也优于射波刀的HDR等效剂量。