Maloney R K
Wilmer Ophthalmological Institute, Baltimore.
Ophthalmology. 1990 Jul;97(7):927-33. doi: 10.1016/s0161-6420(90)32499-5.
Persistent diurnal fluctuations in vision are common after radial keratotomy (RK), associated with a myopic change in refraction and keratometric power as the day progresses. A possible relation between keratometric power and either intraocular pressure (IOP) or corneal hydration was investigated in a cadaver eye model. First, keratometric power was measured before and after RK while IOP was varied from less than 0.5 to 20 mmHg. A nonlinear relation was found; in particular, changes in IOP in the physiologic range had no effect on keratometric power after RK. In a second set of experiments, keratometric power was measured after RK as the dehydrated corneas were gradually hydrated with balanced salt solution. After RK, keratometric power decreased markedly as corneal hydration increased (0.33 diopters [D] per 10-microns increase in thickness). The keratometric power of control corneas was not affected by changes in IOP or hydration. The author concludes that diurnal fluctuations in refraction after RK are probably caused by diurnal fluctuations in corneal hydration rather than changes in IOP.
放射状角膜切开术(RK)后,视力持续出现昼夜波动很常见,且随着白天时间推移,这种波动与屈光和角膜曲率计测量值的近视变化有关。在一个尸体眼模型中,研究了角膜曲率计测量值与眼压(IOP)或角膜水合作用之间可能存在的关系。首先,在RK前后测量角膜曲率计测量值,同时将眼压从低于0.5 mmHg变化至20 mmHg。发现了一种非线性关系;特别是,生理范围内的眼压变化对RK后的角膜曲率计测量值没有影响。在第二组实验中,随着用平衡盐溶液使脱水角膜逐渐水合,测量RK后的角膜曲率计测量值。RK后,随着角膜水合作用增加(厚度每增加10微米,角膜曲率计测量值下降0.33屈光度[D]),角膜曲率计测量值显著下降。对照角膜的角膜曲率计测量值不受眼压或水合作用变化的影响。作者得出结论,RK后屈光的昼夜波动可能是由角膜水合作用的昼夜波动而非眼压变化引起的。