PURPOSES

To evaluate changes in mean keratometry and to compare wound repair with corneal lamellar grafts in rabbit eyes using human synthetic tissue adhesives and 10-0 nylon.

METHODS

Corneal grafts were made using a 6.0-mm-diameter trephine and blades in the eyes of 15 New Zealand white rabbits. Human fibrin tissue adhesive (Tisseel) was used in group 1, human fibrin tissue adhesive (Beriplast P) was used in group 2, polyethylene glycol adhesive (Coseal) was used in group 3, and 8 bite sutures with 10-0 nylon were used in group 4 (control) for lamellar keratoplasty. Four bite sutures were made with 10-0 nylon in groups 1, 2, and 3. Slit-lamp microscopy and keratometry were performed at 3 days and 1, 2, and 4 weeks after the surgery. Histopathologic and electromicroscopic examinations were performed 4 weeks after the surgery.

RESULTS

No inflammation or corneal toxicity was seen in groups 1 and 2. Histologically, a few inflammatory cells were seen in groups 3 and 4. Groups 1, 2, and 3 showed no statistically significant changes in mean keratometry at 4 weeks postoperatively compared with preoperative mean keratometry (Wilcoxon signed-rank test, P = 0.178, 0.208, and 0.889, respectively). The control group showed significant changes in mean keratometry at 4 weeks postoperatively (Wilcoxon signed-rank test, P = 0.018).

CONCLUSIONS

Human fibrin tissue adhesives were well tolerated in rabbit eyes, with no apparent corneal toxicity. Polyethylene glycol adhesive showed more inflammation and insufficient wound repair compared with human fibrin tissue adhesives. Therefore, human fibrin tissue adhesives can be used as an alternative to sutures in lamellar keratoplasty.

摘要

目的

评估平均角膜曲率的变化,并比较使用人合成组织粘合剂和 10-0 尼龙线对兔眼进行角膜层状移植物的伤口修复。

方法

使用 6.0mm 直径环钻和刀片在 15 只新西兰白兔的眼睛中制作角膜移植物。第 1 组使用人纤维蛋白组织粘合剂(Tisseel),第 2 组使用人纤维蛋白组织粘合剂(Beriplast P),第 3 组使用聚乙二醇粘合剂(Coseal),第 4 组(对照组)使用 10-0 尼龙缝线进行层状角膜移植术。第 1、2 和 3 组用 10-0 尼龙缝线做 4 个间断缝线。术后 3 天和 1、2、4 周行裂隙灯显微镜和角膜曲率检查。术后 4 周行组织病理学和电镜检查。

结果

第 1 组和第 2 组未见炎症或角膜毒性。组织学上,第 3 组和第 4 组有少量炎症细胞。与术前平均角膜曲率相比,术后 4 周时,第 1、2 和 3 组的平均角膜曲率没有统计学显著变化(Wilcoxon 符号秩检验,P = 0.178、0.208 和 0.889)。对照组术后 4 周时平均角膜曲率有显著变化(Wilcoxon 符号秩检验,P = 0.018)。

结论

人纤维蛋白组织粘合剂在兔眼中耐受良好,无明显角膜毒性。与人纤维蛋白组织粘合剂相比,聚乙二醇粘合剂显示出更多的炎症和不足的伤口修复。因此,人纤维蛋白组织粘合剂可替代缝线用于层状角膜移植术。