Wytch R, Mitchell C G, Gaffron I D, Neil G, Wardlaw D
Department of Bio-Medical Physics and Bio-Engineering, University of Aberdeen, Scotland, UK.
Clin Biomech (Bristol). 1990 Feb;5(1):35-40. doi: 10.1016/0268-0033(90)90030-A.
Glass fibre bandages are now commonly used for definitive below-knee walking casts, in preference to plaster of Paris, since they are better able to withstand the stresses imposed upon them. This paper describes a technique for recording the cast strains in glass fibre bandages and shows typical stress levels in patient and volunteer casts. A typical map of the stress variations in walking casts during gait in a volunteer has been produced. The study shows that the high stresses recorded along the medial and lateral borders of the foot by the strain gauge technique are confirmed by clinical experience, since this is where failure is most commonly seen in below-knee walking casts. It is concluded that the current generation of polyurethane impregnated glass fibre splinting bandages are too brittle in many cases for below-knee walking casts and that a more flexible fabric would reduce the incidence of cast breakdown.
玻璃纤维绷带如今常用于制作确定性的膝下行走石膏,相较于巴黎石膏更受青睐,因为它们更能承受施加于其上的压力。本文描述了一种记录玻璃纤维绷带中石膏应变的技术,并展示了患者和志愿者石膏中的典型应力水平。已绘制出一名志愿者在步态过程中行走石膏应力变化的典型图谱。该研究表明,应变片技术记录到的沿足部内侧和外侧边缘的高应力得到了临床经验的证实,因为这正是膝下行走石膏最常出现损坏的部位。得出的结论是,当前一代聚氨酯浸渍玻璃纤维夹板绷带在许多情况下对于膝下行走石膏来说太脆,一种更柔韧的织物将降低石膏损坏的发生率。