College of Pharmacy, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.
J Chromatogr B Analyt Technol Biomed Life Sci. 2013 Sep 15;935:41-6. doi: 10.1016/j.jchromb.2013.07.010. Epub 2013 Jul 26.
A rapid, simple and sensitive method based on ultra fast liquid chromatography-tandem spectrometry for the determination of buflomedil in human plasma has been developed and validated using carbamazepine as internal standard. After the precipitation of plasma sample with methanol, the analyte and IS were separated on an Ultimate C18 column (5μm, 2.1mm×50mm, MD, USA) with an isocratic mobile phase composed of acetonitrile and 5mM ammonium acetate in water (60:40, v/v) at a flow rate of 0.25ml/min. The analyte and IS were detected with proton adducts at m/z 308.3-237.1 and m/z 237.2-194.2 in positive ion electrospray ionization and multiple reaction monitoring acquisition mode, respectively. The lower limit of quantification of the method was 23.64ng/ml with a linear dynamic range of 23.64-1182ng/ml for buflomedil. The intra- and inter-batch precisions were less than 5.8%. The developed method was successfully applied to a bioequivalence study of two buflomedil hydrochloride preparations (150mg) in 22 healthy Chinese male volunteers.
建立并验证了一种基于超快速液相色谱-串联质谱的快速、简单、灵敏的方法,用于测定人血浆中的丁苯酞。以卡马西平为内标,采用甲醇沉淀血浆样品后,用 Ultimate C18 柱(5μm,2.1mm×50mm,MD,美国)进行分离,以乙腈和 5mM 乙酸铵水溶液(60:40,v/v)为流动相,流速为 0.25ml/min,采用等度洗脱。采用正离子电喷雾电离和多反应监测采集模式,以质子加合物的形式,在 m/z 308.3-237.1 和 m/z 237.2-194.2 处分别检测分析物和内标。该方法的定量下限为 23.64ng/ml,丁苯酞的线性动力学范围为 23.64-1182ng/ml。该方法的日内和日间精密度均小于 5.8%。该方法成功应用于 22 名健康中国男性志愿者中两种盐酸丁苯酞制剂(150mg)的生物等效性研究。