Suppr超能文献

基于倒谱分析的儿童嗓音频率和扰力度测量的一致性:提高记录稳定性的一种方法。

Consistency of voice frequency and perturbation measures in children using cepstral analyses: a movement toward increased recording stability.

机构信息

Department of Otolaryngology-Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA 02114, USA.

出版信息

JAMA Otolaryngol Head Neck Surg. 2013 Aug 1;139(8):811-6. doi: 10.1001/jamaoto.2013.3926.

Abstract

IMPORTANCE

Few studies have evaluated the pediatric voice objectively using acoustic measurements. Furthermore, consistency of these measurements across time, particularly for continuous speech, has not been evaluated.

OBJECTIVES

(1) To evaluate normal pediatric voice frequency and perturbation using both time-based and frequency-based acoustic measurements, and (2) to determine if continuous speech samples facilitate increased recording stability. DESIGN Prospective, longitudinal study.

SETTING

Pediatric otolaryngology practice within a tertiary hospital.

PARTICIPANTS

Forty-three children, ages 4 to 17 years. INTERVENTION OR EXPOSURE: Sustained vowel utterances and continuous speech samples, which included 4 Consensus Auditory-Perceptual Evaluation of Voice (CAPE-V) sentences and the first sentence of the "rainbow passage" ("A rainbow is a division of white light into many beautiful colors that takes the shape of a long round arch, with its path high above and its 2 ends apparently beyond the horizon") were obtained at 2 time points.

MAIN OUTCOME AND MEASURE

Intraclass correlation coefficients (ICCs) were calculated to assess reliability between speech samples.

RESULTS

Fundamental frequency of sustained vowel utterances had excellent reliability (ICC ≥ 0.94). Time-based analyses of perturbation in sustained vowel utterances demonstrated poor reliability (ICC < 0.40), while frequency-based analyses of perturbation for these utterances demonstrated good to excellent reliability (ICC > 0.40). Fundamental frequency of continuous speech sample had excellent reliability (ICC > 0.94). Frequency-based analyses of continuous speech samples demonstrated excellent reliability (ICC > 0.75) for all but 1 variable, which demonstrated good reliability (cepstral-spectral index of dysphonia of the all voiced sample; ICC =0.72).

CONCLUSIONS AND RELEVANCE

Sustained vowel utterance and continuous speech samples provide consistent measures of fundamental frequency. Frequency-based analysis of sustained vowel recordings improves the reliability of perturbation measures. Continuous speech recordings can be obtained in children and demonstrate good to excellent reliability across recordings. This suggests that frequency-based analysis of continuous speech may be more representative of a child's voice and therefore may be of use in the study both of the developmental changes of the pediatric voice as well as the study of vocal changes pretreatment and posttreatment in children with voice disorders.

摘要

重要性

很少有研究使用声学测量客观评估儿科嗓音。此外,这些测量在时间上的一致性,特别是对于连续语音,尚未得到评估。

目的

(1)使用基于时间和基于频率的声学测量评估正常儿科嗓音频率和扰频,以及(2)确定连续语音样本是否有助于提高记录稳定性。

设计

前瞻性、纵向研究。

地点

三级医院的儿科耳鼻喉科诊所。

参与者

43 名年龄在 4 至 17 岁的儿童。

干预

获得两次持续元音发音和连续语音样本,包括 4 个共识听觉感知嗓音评估(CAPE-V)句子和“彩虹通道”(“彩虹是白光被分解成许多美丽的颜色,呈现出长圆形拱的形状,路径高在上面,其两端显然超出地平线”)的第一个句子。

主要结果和测量

计算组内相关系数(ICC)评估两次语音样本之间的可靠性。

结果

持续元音发音的基频具有极好的可靠性(ICC≥0.94)。持续元音发音的扰频基于时间的分析显示可靠性差(ICC<0.40),而这些发音的基于频率的扰频分析显示出良好至极好的可靠性(ICC>0.40)。连续语音样本的基频具有极好的可靠性(ICC>0.94)。除了 1 个变量(所有浊音样本的声门噪声的倒频谱-光谱指数;ICC=0.72)显示良好的可靠性外,连续语音样本的频率分析显示出极好的可靠性(ICC>0.75)。

结论和相关性

持续元音发音和连续语音样本提供了基本频率的一致测量值。持续元音发音记录的基于频率的分析提高了扰频测量的可靠性。儿童可以获得连续语音记录,并且在两次记录中都表现出良好至极好的可靠性。这表明,连续语音的基于频率的分析可能更能代表儿童的声音,因此可能有助于研究儿科嗓音的发育变化,以及儿童嗓音障碍的治疗前和治疗后的嗓音变化研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验