• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Pistol-grip Syringe holder (Cameco syringe pistol) in fine needle aspiration Biopsy: any advantages over the use of direct finger grip?

作者信息

Mayun A A, Nggada H A, Abdulazzez J O, Musa A B, Pindiga U H, Khalil M I

机构信息

Departments of Human Pathology and 1Medical Laboratory Science, College of Medical Sciences, University of Maiduguri, Nigeria.

出版信息

Niger Postgrad Med J. 2013 Jun;20(2):116-9.

PMID:23959352
Abstract

AIMS AND OBJECTIVES

The study seeks to determine the advantages of using the pistol-grip syringe holder in the performance of FNAB over the use of direct finger grip method.

PATIENTS AND METHODS

The skin is cleaned with gauze soaked in methylated spirit and the lump is located and firmly held between the thumb and fore finger of the free hand. The syringe is held by the out side of the barrel or by pistol-grip, and the needle tip pushed into the lesion. The plunger is partially retracted, creating a negative pressure. The cutting edge of the needle tip frees the cells inside the lesion which are sucked into the fine bore of the needle. The contents of the needle are then emptied on a microscopic slide and thinly smeared. The slides are then fixed in alcohol and later stained. These were examined under the microscope and a comparison between the aspirations using pistol-grip and direct finger grip was made.

RESULTS

A total of 266 cases of FNABs were carried out from 1st January to 31st December, 2008. There were 89 breast cases out of which 42 (47%) had pistol-grip method and 47 (53%) had direct finger grip method; 74 thyroid cases out of which 28 (38%) were pistol-grip and 46 (62%) were direct finger grip cases; 56 cases of lymph node FNABs of which 18(32%) and 38 (68%) had pistol-grip and direct finger grip methods respectively. There were 23 cases of salivary gland FNABs having 8 (35%) and 15 (65%) as pistol-grip and direct finger grip methods respectively. Marked cellularity was observed in the majority of cases using both methods of FNABs.

CONCLUSION

This study has shown that the use of pistol-grip syringe holder in the performance of FNABs has no significant advantage compared to the direct finger grip method.

摘要

相似文献

1
Pistol-grip Syringe holder (Cameco syringe pistol) in fine needle aspiration Biopsy: any advantages over the use of direct finger grip?
Niger Postgrad Med J. 2013 Jun;20(2):116-9.
2
Fine-needle aspiration biopsy using a newly-developed pencil-grip syringe holder.
Diagn Cytopathol. 1999 Feb;20(2):99-104. doi: 10.1002/(sici)1097-0339(199902)20:2<99::aid-dc12>3.0.co;2-r.
3
[Fine needle capillary cytology versus fine needle aspiration cytology--a comparison of quality between puncture techniques in the ENT area].[细针毛细血管细胞学与细针穿刺细胞学——耳鼻喉科领域两种穿刺技术质量的比较]
Laryngorhinootologie. 1997 Jun;76(6):358-63. doi: 10.1055/s-2007-997442.
4
Fine-needle aspiration biopsy for breast lesions: a comparison between two devices for obtaining cytological samples.乳腺病变的细针穿刺活检:两种获取细胞学样本设备的比较。
Sao Paulo Med J. 2005 Nov 3;123(6):271-6. doi: 10.1590/s1516-31802005000600004. Epub 2006 Jan 20.
5
Large-core needle biopsy versus fine-needle aspiration biopsy in solid breast lesions: comparison of costs and diagnostic value.实性乳腺病变中粗针穿刺活检与细针穿刺抽吸活检的比较:成本与诊断价值对比
Acta Radiol. 2008 Oct;49(8):863-9. doi: 10.1080/02841850802235751.
6
A comparison of specimen adequacy in fine needle aspiration biopsies performed by pathologists, trained nursing staff and clinicians.
Trop Doct. 2012 Apr;42(2):97-8. doi: 10.1258/td.2011.110312. Epub 2012 Feb 10.
7
Control and performance characteristics of eight different suction biopsy devices.八种不同抽吸活检设备的控制与性能特征
J Vasc Interv Radiol. 2006 Oct;17(10):1657-69. doi: 10.1097/01.RVI.0000236837.47302.8E.
8
A new syringe for fine needle aspiration biopsy.一种用于细针穿刺活检的新型注射器。
Acta Cytol. 1993 Jan-Feb;37(1):29-33.
9
Modification of a syringe for aspiration biopsy.
Radiology. 1993 Nov;189(2):614. doi: 10.1148/radiology.189.2.8210397.
10
Putting aspiration back into thyroid fine-needle biopsy-the re-emerging role of vacuum assistance.将负压抽吸重新应用于甲状腺细针穿刺活检——真空辅助的再度兴起的作用。
Cancer Cytopathol. 2012 Dec 25;120(6):366-72. doi: 10.1002/cncy.21256. Epub 2012 Nov 15.