High-performance anion-exchange chromatography with pulsed amperometric detection (HPAE-PAD) is an established technique for the carbohydrate analysis of glycoproteins. HPAE-PAD is routinely used for determinations of monosaccharide, sialic acid, mannose-6-phosphate (M-6-P), and oligosaccharide contents of a glycoprotein. This is true for both the initial investigation of a glycoprotein and routine assays of recombinant therapeutic glycoproteins. This contribution reviews the fundamentals of HPAE-PAD, recent technological improvements, and advances in the last ten years in its application to carbohydrate analysis of glycoproteins. The application areas reviewed include monosaccharide determinations, sialic acid determinations, M-6-P determinations, sugar alcohol determinations, analysis of polysialic acids, neutral and charged oligosaccharide analysis, following glycosidase and glycosyltransferase reactions, and coupling HPAE-PAD to mass spectrometry (MS).
高效阴离子交换色谱-脉冲安培检测(HPAE-PAD)是一种用于糖蛋白碳水化合物分析的成熟技术。HPAE-PAD 常用于测定糖蛋白中单糖、唾液酸、甘露糖-6-磷酸(M-6-P)和寡糖的含量。无论是对糖蛋白的初步研究还是对重组治疗性糖蛋白的常规分析,HPAE-PAD 都是如此。本综述介绍了 HPAE-PAD 的基本原理、近年来的技术改进以及过去十年在糖蛋白碳水化合物分析中的应用进展。综述的应用领域包括单糖测定、唾液酸测定、M-6-P 测定、糖醇测定、多唾液酸分析、中性和带电寡糖分析、糖苷酶和糖基转移酶反应后以及将 HPAE-PAD 与质谱(MS)耦合。