黏结剂对玻璃纤维桩拉伸粘结强度的影响:一项体外研究。

Effect of luting agents on the tensile bond strength of glass fiber posts: An in vitro study.

机构信息

Associate Professor, Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.

出版信息

J Prosthet Dent. 2013 Sep;110(3):216-22. doi: 10.1016/S0022-3913(13)60360-1.

Abstract

STATEMENT OF PROBLEM

Fiber posts can fail because of loss of retention; and it is unknown which luting agent provides the highest bond strength.

PURPOSE

The purpose of this study was to investigate the tensile bond strength of glass fiber posts luted to premolar teeth with 6 resin composite luting agents.

MATERIAL AND METHODS

Ninety-six single-rooted extracted human mandibular premolars were sectioned 2 mm coronal to the most incisal point of the cementoenamel junction. Root canals were instrumented and obturated with laterally condensed gutta percha and root canal sealer (AH26). Gutta percha was removed from the canals to a depth of 8 mm and diameter post spaces with a 1.5 mm were prepared. The specimens were divided into the following 6 groups according to the luting agent used (n=16): Group V, Variolink II; Group A, RelyX ARC; Group N, Multilink N; Group U, RelyX Unicem; Group P, ParaCore; Group F, MultiCore Flow. Each specimen was secured in a universal testing machine and a separating load was applied at a rate of 0.5 mm/min. The forces required to dislodge the posts were recorded. A 1-way analysis of variance (ANOVA) was applied to the mean retentive strengths of various cement materials (α=.05).

RESULTS

Significant differences were recorded among the 6 cement types (P<.001). Three materials provided statistically equivalent mean bond strengths (RelyX Unicem, Paracore, and MultiCore Flow) that were significantly greater than for the other 3 materials.

CONCLUSIONS

Fiber posts luted with RelyX Unicem, Paracore, and MultiCore Flow demonstrated significantly higher bond strengths.

摘要

问题陈述

纤维桩可能会因固位丧失而失效;而且,哪种粘固剂具有最高的粘结强度尚不清楚。

目的

本研究旨在调查 6 种树脂复合粘固剂粘结到前磨牙上的玻璃纤维桩的拉伸粘结强度。

材料和方法

96 颗单根人下颌前磨牙从牙釉牙骨质界最切端向冠方 2mm 处截断。根管用侧向压缩牙胶和根管封闭剂(AH26)进行器械和填充。将牙胶从根管中取出至 8mm 深,并用 1.5mm 的直径制备桩腔。根据使用的粘固剂将标本分为以下 6 组(n=16):组 V,Variolink II;组 A,RelyX ARC;组 N,Multilink N;组 U,RelyX Unicem;组 P,ParaCore;组 F,MultiCore Flow。将每个标本固定在万能试验机上,以 0.5mm/min 的速率施加分离载荷。记录脱位桩所需的力。对各种粘结材料的平均固位强度进行单因素方差分析(ANOVA)(α=.05)。

结果

6 种粘结剂的粘结强度存在显著差异(P<.001)。三种材料(RelyX Unicem、Paracore 和 MultiCore Flow)的平均粘结强度具有统计学等效性,显著大于其他三种材料。

结论

用 RelyX Unicem、Paracore 和 MultiCore Flow 粘结的纤维桩具有更高的粘结强度。