Reference range of fetal cisterna magna volume by three-dimensional ultrasonography using the VOCAL method.

作者信息

Araujo Júnior Edward, Passos Ana Paula, Bruns Rafael Frederico, Nardozza Luciano Marcondes Machado, Moron Antonio Fernandes

机构信息

Department of Obstetrics, Federal University of São Paulo (UNIFESP) , São Paulo-SP , Brazil and.

出版信息

J Matern Fetal Neonatal Med. 2014 Jul;27(10):1023-8. doi: 10.3109/14767058.2013.847419. Epub 2013 Oct 22.

Abstract

OBJECTIVE

To determine reference values for the fetal cisterna magna volume by three-dimensional ultrasonography (3DUS) using the virtual organ computer-aided analysis (VOCAL) method.

METHODS

A cross-sectional study was conducted with 224 healthy pregnant women between 17 and 29 completed weeks. Measurement of the fetal cisterna magna volume was performed in the standard axial plane of the transverse diameter of the cerebellum through the VOCAL method with a 30° angle. For the determination of reference values, polynomial regressions with adjustments by the coefficient of determination (R(2)) were held. The reliability and agreement were made by the intra-class correlation coefficient (ICC) and limits of agreement of the Bland-Altman graph.

RESULTS

The average of the fetal cisterna magna volume ranged from 0.73 ± 0.25 to 3.79 ± 1.10 cm(3) between 17 and 29 weeks, respectively. Correlation was observed between the fetal cisterna magna volume and the gestational age (GA), best represented by a quadratic equation: -1.918+0.0284 × GA + 0.0065 × GA(2) (R(2 )= 0.67). It was observed good reliability and intra-observer agreement, with ICC = 0.92 and 95% limits of agreement (-49.7; 48.4). There was low inter-observer reliability and agreement, with ICC = 0.58 and 95% limits of agreement (-114.0; 80.2).

CONCLUSION

Reference values for the fetal cisterna magna volume by 3DUS using the VOCAL method were determined and showed good agreement and intra-observer reliability.

摘要

目的

采用虚拟器官计算机辅助分析(VOCAL)方法,通过三维超声(3DUS)确定胎儿小脑延髓池容积的参考值。

方法

对224例孕17至29周的健康孕妇进行横断面研究。通过VOCAL方法,在小脑横径的标准轴平面以30°角测量胎儿小脑延髓池容积。为确定参考值,采用决定系数(R²)调整的多项式回归。通过组内相关系数(ICC)和Bland-Altman图的一致性界限评估可靠性和一致性。

结果

孕17至29周期间,胎儿小脑延髓池容积平均值分别为0.73±0.25至3.79±1.10 cm³。观察到胎儿小脑延髓池容积与孕周(GA)之间存在相关性,最佳拟合方程为二次方程:-1.918 + 0.0284×GA + 0.0065×GA²(R² = 0.67)。观察到良好的可靠性和观察者内一致性,ICC = 0.92,95%一致性界限为(-49.7;48.4)。观察者间可靠性和一致性较低,ICC = 0.58,95%一致性界限为(-114.0;80.2)。

结论

采用VOCAL方法通过3DUS确定了胎儿小脑延髓池容积的参考值,显示出良好的一致性和观察者内可靠性。

相似文献

1
Reference range of fetal cisterna magna volume by three-dimensional ultrasonography using the VOCAL method.
J Matern Fetal Neonatal Med. 2014 Jul;27(10):1023-8. doi: 10.3109/14767058.2013.847419. Epub 2013 Oct 22.
2
Reference ranges of fetal cisterna magna length and area measurements by 3-dimensional ultrasonography using the multiplanar mode.
J Child Neurol. 2015 Feb;30(2):209-15. doi: 10.1177/0883073814535496. Epub 2014 May 19.
5
Three-dimensional volumetric study with VOCAL in normal and abnormal posterior fossa fetuses.
J Matern Fetal Neonatal Med. 2020 May;33(10):1647-1655. doi: 10.1080/14767058.2018.1526902. Epub 2018 Oct 29.
6
Measuring fetal volume during late first trimester by three-dimensional ultrasonography using virtual organ computer-aided analysis.
Ultrasound Med Biol. 2013 Sep;39(9):1552-9. doi: 10.1016/j.ultrasmedbio.2013.02.003. Epub 2013 Jun 19.
10
The cisterna magna size in normal second-trimester fetuses.
J Perinat Med. 2007;35(3):217-9. doi: 10.1515/JPM.2007.060.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验