Suppr超能文献

应用三维超声多平面模式二维法测量胎儿小脑延髓池容积的参考区间

Reference intervals of fetal cisterna magna volume by two-dimensional method using the multiplanar mode of three-dimensional ultrasonography.

作者信息

Nardozza Luciano Marcondes Machado, Passos Ana Paula, Araujo Júnior Edward, Bruns Rafael Frederico, Moron Antonio Fernandes

机构信息

Private Docents, Associate Professors, Obstetrics Department, Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil.

Master, Physician Assistant at Clínica Fetalmed, Curitiba, PR, Brazil.

出版信息

Radiol Bras. 2014 Jul-Aug;47(4):201-5. doi: 10.1590/0100-3984.2013.1852.

Abstract

OBJECTIVE

To establish reference intervals for the fetal cisterna magna volume by means of two-dimensional (2D) method using the multiplanar mode of three-dimensional ultrasonography.

MATERIALS AND METHODS

Cross-sectional study with 224 healthy pregnant women between the 17th and 29th gestational weeks. The volume was automatically obtained by multiplying the three major axes in axial and sagittal planes by the constant 0.52. Polynomial regression was utilized to establish the correlation between fetal cisterna magna volume and gestational age, with adjustments by coefficient of determination (R(2)). Reliability and agreement were obtained by intraclass correlation coefficient (ICC) and limits of agreement, respectively.

RESULTS

Mean fetal cisterna volume with the 2D method ranged from 0.71 ± 0.19 cm(3) to 4.18 ± 0.75 cm(3) at the 17th and 29th weeks, respectively. The authors observed a good correlation between fetal cisterna magna volume and gestational age (R(2) = 0.67), excellent intraobserver reliability and agreement with ICC = 0.89 and limits of agreement 95% (-52.0; 51.8), respectively, and low interobserver reliability and agreement with ICC = 0.64 and limits of agreement 95% (-110.1; 84.6), respectively.

CONCLUSION

Reference intervals for fetal cisterna magna volume by means of 2D method using the multiplanar mode of three-dimensional ultrasonography were established and presented excellent intraobserver reliability and agreement.

摘要

目的

采用三维超声多平面模式的二维(2D)方法建立胎儿小脑延髓池容积的参考区间。

材料与方法

对224例孕17至29周的健康孕妇进行横断面研究。通过将轴向和矢状面的三个主要轴乘以常数0.52自动获得容积。利用多项式回归建立胎儿小脑延髓池容积与孕周之间的相关性,并通过决定系数(R²)进行调整。分别通过组内相关系数(ICC)和一致性界限获得可靠性和一致性。

结果

二维方法测得的胎儿小脑延髓池平均容积在第17周和第29周分别为0.71±0.19 cm³至4.18±0.75 cm³。作者观察到胎儿小脑延髓池容积与孕周之间具有良好的相关性(R² = 0.67),观察者内可靠性极佳,一致性良好,ICC分别为0.89,一致性界限95%为(-52.0;51.8),而观察者间可靠性和一致性较低,ICC分别为0.64,一致性界限95%为(-110.1;84.6)。

结论

采用三维超声多平面模式的二维方法建立了胎儿小脑延髓池容积的参考区间,且观察者内可靠性和一致性极佳。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d156/4337116/294cff91003a/rb-47-04-0201-g01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验