OBJECTIVES

Carbon monoxide (CO) poisoning frequently affects repolarization, resulting in abnormal electrocardiography findings. The goal of this study was to examine the effect of CO poisoning on the novel transmyocardial repolarization parameters T peak-T end (Tp-e), Tp-e dispersion, and Tp-e/QT and the relationship of these parameters to myocardial injury (MI).

METHODS

This prospective study included 94 patients with CO poisoning and 40 healthy controls. Participants received an electrocardiography and had their blood drawn at admission and 6 and 24 hours after admission. The QT, Tp-e, Tp-e dispersion, and the Tp-e/QT ratio were calculated. Myocardial injury was determined based on an elevation in troponin any time during the first 24 hours. The patients were divided into 2 subgroups: those with and without MI.

RESULTS

T peak-T end, Tp-e dispersion, and the Tp-e/QT ratio were higher at admission than after 6 and 24 hours of hospitalization and were higher than the control group (P < .001). There was a correlation between the carboxyhemoglobin level at admission and Tp-e and Tp-e dispersion (P < .001). The MI subgroup (n = 14) had a higher Tp-e at admission than did the non-MI subgroup (n = 80) (96 [11] milliseconds vs 87 [12] milliseconds, P = .03). There were no any significant differences in the Tp-e dispersion or the Tp-e/QT ratio between the 2 MI subgroups. Receiver operating characteristic analysis showed that a Tp-e cutoff value for MI of 91.5 milliseconds had a sensitivity of 72.7% and a specificity of 67.2%.

CONCLUSION

Transmyocardial repolarization parameters indicative of arrhythmia were prolonged in patients with CO poisoning. T peak-T end was associated with MI.

摘要

目的

一氧化碳(CO)中毒常影响复极,导致心电图异常。本研究旨在探讨 CO 中毒对新的跨心肌复极参数 T 峰值-T 末(Tp-e)、Tp-e 离散度和 Tp-e/QT 的影响,以及这些参数与心肌损伤(MI)的关系。

方法

本前瞻性研究纳入 94 例 CO 中毒患者和 40 例健康对照者。所有患者入院时、入院后 6 小时和 24 小时均接受心电图检查和采血。计算 QT、Tp-e、Tp-e 离散度和 Tp-e/QT 比值。根据入院后 24 小时内任意时间肌钙蛋白升高确定心肌损伤。将患者分为 MI 组和非 MI 组。

结果

入院时 Tp-e、Tp-e 离散度和 Tp-e/QT 比值均高于入院后 6 小时和 24 小时,且高于对照组(P<0.001)。入院时碳氧血红蛋白水平与 Tp-e 和 Tp-e 离散度呈正相关(P<0.001)。MI 组(n=14)入院时 Tp-e 高于非 MI 组(n=80)(96[11]ms 比 87[12]ms,P=0.03)。2 组 MI 患者 Tp-e 离散度和 Tp-e/QT 比值无统计学差异。受试者工作特征曲线分析显示,Tp-e 预测 MI 的截断值为 91.5ms 时,敏感度为 72.7%,特异度为 67.2%。

结论

CO 中毒患者跨心肌复极参数提示心律失常延长。Tp-e 与 MI 相关。