University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care , Utrecht , the Netherlands.
Scand J Clin Lab Invest. 2013 Dec;73(8):627-34. doi: 10.3109/00365513.2013.841985. Epub 2013 Oct 14.
Point-of-care (POC) C-reactive protein (CRP) testing is increasingly used in primary care to assist general practitioners (GPs) in the diagnostic workup for various complaints. The present study compares analytical performance, agreement and user-friendliness of five of these POC CRP tests.
The following five POC CRP tests were evaluated: Afinion and NycoCard Reader II (both Alere), Eurolyser Smart 700/340 (Eurolyser), QuikRead go and QuikRead 101 (both Orion Diagnostica). Results were compared with those of a standard immunoturbidimetric method performed on a routine analyzer (Olympus AU 2700, Beckman Coulter). Analytical performance and agreement with the laboratory standard for the five different POC tests were analyzed. Subsequently, user-friendliness of the POC tests was assessed.
Within-day CVs varied from 2.6% (QuikRead go) to 19.4% (Eurolyser Smart 700/340) for low CRP values (< 20 mg/L), and 1.1% (QuikRead go) to 17.5% (Eurolyser Smart 700/340) for high values (> 100 mg/L). Between-day CVs varied from 4.6% (Afinion) to 30.5% (Eurolyser Smart 700/340) for low values and 4.0% (QuikRead go) to 18.0% (Eurolyser Smart 700/340) for high values. With high CRP values (> 100 mg/L) agreement with the laboratory standard systematically decreased for all POC tests. Regarding user-friendliness Afinion and Eurolyser Smart 700/340 were judged easiest to operate.
Analytical performance, agreement, and user-friendliness of the POC CRP tests varied considerably, yet overall four devices showed adequate analytical performance and agreement.
即时检测(POC)C 反应蛋白(CRP)检测在初级保健中越来越多地被用于协助全科医生(GP)对各种病症进行诊断。本研究比较了五种 POC CRP 检测的分析性能、一致性和易用性。
评估了以下五种 POC CRP 检测:Afinion 和 NycoCard Reader II(均为 Alere)、Eurolyser Smart 700/340(Eurolyser)、QuikRead go 和 QuikRead 101(均为 Orion Diagnostica)。结果与常规分析仪(Olympus AU 2700、Beckman Coulter)上进行的标准免疫比浊法进行了比较。分析了五种不同 POC 检测的分析性能和与实验室标准的一致性。随后,评估了 POC 检测的易用性。
低值(<20mg/L)的日内变异系数(CV)从 2.6%(QuikRead go)到 19.4%(Eurolyser Smart 700/340)不等,高值(>100mg/L)的日内 CV 从 1.1%(QuikRead go)到 17.5%(Eurolyser Smart 700/340)不等。低值的日间 CV 从 4.6%(Afinion)到 30.5%(Eurolyser Smart 700/340)不等,高值的日间 CV 从 4.0%(QuikRead go)到 18.0%(Eurolyser Smart 700/340)不等。对于高 CRP 值(>100mg/L),所有 POC 检测与实验室标准的一致性均系统性降低。关于易用性,Afinion 和 Eurolyser Smart 700/340 被认为操作最简单。
POC CRP 检测的分析性能、一致性和易用性差异很大,但总体而言,四种设备均显示出足够的分析性能和一致性。