Opt Lett. 2013 Nov 1;38(21):4277-80. doi: 10.1364/OL.38.004277.
Highly birefringent (Hi-Bi) microfiber-based fiber loop mirrors (FLMs) were studied for tunable comb filters and refractive index (RI) sensors. The use of two cascaded Hi-Bi microfibers instead of a single microfiber allows more flexibility in controlling the transmission/reflection characteristics of the FLM. The length of Hi-Bi microfibers is of the order of centimeters, one or even more than two orders of magnitude shorter than the conventional Hi-Bi fiber-based FLM devices. The transmission/reflection spectra are sensitive to the RI surrounding the microfibers, and RI sensitivity of 20,745 nm/RIU was experimentally demonstrated.