Cakiryildiz C, Mehta P J, Rahmen W, Schoenleber D
J Pharm Sci. 1975 Oct;64(10):1692-7. doi: 10.1002/jps.2600641024.
A multichannel continuous-flow apparatus for dissolution rate measurements is described. Typical data are presented to demonstrate its utility for studies with bulk drug powders as well as with tablets and capsules without any change of setup. Procedures are given for the preparation of powder samples for dissolution studies and for a simple method of changing pH for "retard" tablets. The precision in dissolution rates obtained with this apparatus and method is 1-10% mean RSD. The advantages of the method are flexibility, reproducibility, and ability to obtain data in integral or differential form.
描述了一种用于溶出速率测量的多通道连续流动装置。给出了典型数据,以证明其在研究原料药粉末以及片剂和胶囊时的实用性,且无需改变装置设置。给出了用于溶出研究的粉末样品制备程序,以及一种用于“缓释”片剂改变pH值的简单方法。用该装置和方法获得的溶出速率精度为平均相对标准偏差1-10%。该方法的优点是灵活性、可重复性以及能够以积分或微分形式获取数据。