Suppr超能文献

针对几乎没有或仅有一些血管和动物模型联合使用经验的介入放射科医生,开展关于选择性下腔静脉滤器置入和取出的培训。

Training on insertion and retrieval of optional inferior vena cava filters for interventional radiologists with little or just some experience with the combined use of blood vessel and animal models.

作者信息

Yamagami Takuji, Hasebe Terumitsu, Yoshimatsu Rika, Matsumoto Tomohiro, Hashimoto Takeshi, Komemushi Atsushi, Kamei Seiji, Hagihara Makiyo, Sato Yozo, Kondo Hiroshi, Inoue Masanori, Nakatsuka Atsuhiro, Takahashi Makoto, Koizumi Jun, Saito Hiroya

机构信息

Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-Ku, Hiroshima, 734-8551 Japan.

出版信息

Springerplus. 2013 Jul 30;2:354. doi: 10.1186/2193-1801-2-354. eCollection 2013.

Abstract

PURPOSE

To evaluate the usefulness of a tool that we developed to simulate performance of insertion and retrieval of optional inferior vena cava filters to be additionally used in training of beginners with an animal model.

SUBJECTS AND METHODS

Thirty young doctors who had little or no experience in insertion and/or retrieval of filters were subjects of this study to evaluate the training tool. Eleven trainees practiced both insertion and retrieval of filters first with the animal model then with the blood vessel model while 19 trainees first practiced with the blood vessel model then with the animal model.

RESULTS

All trainees successfully inserted the filter. Two of the 11 trainees who used the animal model before the blood vessel model failed in retrieval, and 2 of the 19 trainees who used the blood vessel model before the animal model failed. In the former group, mean time for filter implantation and withdrawal in the animal model was 75 ± 62 s and 341 ± 238 s, respectively, and in the latter group were 54 ± 16 s and 311 ± 236 s, respectively.

CONCLUSION

Training with the combination of a blood vessel model and animal model is helpful for beginners to learn to insert and withdraw optional filters.

摘要

目的

评估我们开发的一种工具的实用性,该工具用于模拟额外使用的可选下腔静脉滤器的插入和取出操作,以用于动物模型的初学者培训。

对象与方法

30名在滤器插入和/或取出方面几乎没有经验的年轻医生作为本研究对象来评估该培训工具。11名学员先使用动物模型练习滤器的插入和取出,然后使用血管模型练习;而19名学员先使用血管模型练习,然后使用动物模型练习。

结果

所有学员均成功插入滤器。在血管模型之前使用动物模型的11名学员中有2名取出失败,在动物模型之前使用血管模型的19名学员中有2名取出失败。在前一组中,动物模型中滤器植入和取出的平均时间分别为75±62秒和341±238秒,在后一组中分别为54±16秒和311±236秒。

结论

血管模型和动物模型相结合的培训有助于初学者学习插入和取出可选滤器。