Simpson-White R W, Chojnowski A J
Norfolk and Norwich University Hospital NHS Foundation Trust, Norwich, UK
Norfolk and Norwich University Hospital NHS Foundation Trust, Norwich, UK.
J Hand Surg Eur Vol. 2014 Jul;39(6):575-81. doi: 10.1177/1753193413511946. Epub 2013 Nov 22.
The purpose of this retrospective cohort study was to evaluate the outcomes of 18 primary pyrocarbon metacarpophalangeal joint replacements in 10 patients, performed for primary osteoarthritis. The mean age at operation was 66 years and mean follow-up was 58.6 months. The arc of motion improved from a mean of 30° to 40° and the mean QuickDASH score improved from 35 to 17. All except one patient were satisfied with their outcomes. Radiographically, there has been no evidence of dislocation or overt loosening, although there has been subsidence of some components up to 5 mm. One index finger implant was revised to a silastic implant for perceived alteration of precision pinch. Other complications included one intra-operative fracture that united and an asymptomatic stem fracture of one proximal phalangeal component. We continue to use the implant and aim to review our experience in a further 5 years.
这项回顾性队列研究的目的是评估10例患者中18例原发性焦碳酸掌指关节置换术治疗原发性骨关节炎的疗效。手术时的平均年龄为66岁,平均随访时间为58.6个月。活动弧度从平均30°改善到40°,平均QuickDASH评分从35分提高到17分。除1例患者外,所有患者对其治疗效果均满意。影像学检查显示,尽管有些组件出现了高达5毫米的下沉,但没有脱位或明显松动的迹象。一枚食指植入物因感觉捏力精度改变而翻修为硅橡胶植入物。其他并发症包括1例术中骨折已愈合,以及1例近端指骨组件无症状的柄部骨折。我们继续使用该植入物,并计划在未来5年回顾我们的经验。