Standardization of the measurement of electrolyte concentrations in serum is of considerable interest for quality assurance in patient care. To promote the ongoing process of standardization we developed candidate reference measurement procedures of highest metrological order for Cl, K, Na, Ca, Mg, and Li using ICP-(ID) SFMS.
Serum samples were diluted with 4 mmol/L nitric acid and were spiked with the internal standard for quantification, separately for each analyte. The samples were introduced in the ICP-SFMS device by continuous infusion using a peristaltic pump. The measurement results were compared with reference measurement procedure values obtained by atom absorption spectroscopy, flame emission spectroscopy, and coulometry. The measurement accuracy and precision was calculated by analyzing certified reference materials and EQAS samples.
The mean coefficient of variation (CV) of the ICP-MS procedures for the serum samples was 0.65% for Cl, 0.46% for K, 0.51% for Na, 0.77% for Ca, 0.78% for Mg, and 0.58% for Li. The mean bias from target values of NIST certified reference materials was +0.85% for Cl, -0.46% for K, +0.68% for Na, -0.21% for Ca, +0.27% for Mg, and -0.39% for Li.
Candidate reference measurement procedures for 6 electrolytes were developed by high performance magnetic sector field ICP-MS fulfilling the requirements of ISO 15193:2009 for reference measurement procedures with traceability to SI according to ISO 17511:2003 and can be used for setting target values in EQAS and for certification of reference materials.
血清中电解质浓度测量的标准化对于患者护理的质量保证具有重要意义。为推动标准化进程,我们使用电感耦合等离子体质谱-(同位素稀释)扇形磁场质谱法(ICP-(ID) SFMS)开发了用于氯、钾、钠、钙、镁和锂的最高计量级别的候选参考测量程序。
血清样本用4 mmol/L硝酸稀释,并分别为每种分析物加入内标进行定量。使用蠕动泵通过连续进样将样本引入ICP-SFMS设备。将测量结果与通过原子吸收光谱法、火焰发射光谱法和库仑法获得的参考测量程序值进行比较。通过分析有证参考物质和室间质评样本计算测量的准确度和精密度。
血清样本的ICP-MS程序的平均变异系数(CV),氯为0.65%,钾为0.46%,钠为0.51%,钙为0.77%,镁为0.78%,锂为0.58%。与美国国家标准与技术研究院(NIST)有证参考物质目标值的平均偏差,氯为+0.85%,钾为 -0.46%,钠为+0.68%,钙为 -0.21%,镁为+0.27%,锂为 -0.39%。
通过高性能扇形磁场ICP-MS开发了6种电解质的候选参考测量程序,符合ISO 15193:2009对根据ISO 17511:2003可溯源至国际单位制(SI)的参考测量程序的要求,可用于设定室间质评的目标值和参考物质的认证。