Suppr超能文献

用于后牙单颗牙替换的预成二氧化锆种植基台:3年功能后的成功与失败情况

Pre-fabricated zirconium dioxide implant abutments for single-tooth replacement in the posterior region: success and failure after 3 years of function.

作者信息

Nothdurft Frank P, Nonhoff Joerg, Pospiech Peter R

机构信息

Department of Prosthetic Dentistry and Dental Materials Sciences, Saarland University , Homburg/Saar , Germany.

出版信息

Acta Odontol Scand. 2014 Jul;72(5):392-400. doi: 10.3109/00016357.2013.863970. Epub 2013 Dec 5.

Abstract

OBJECTIVE

Zirconia implant abutments have gained a much broader clinical use over the past few years. The aim of the present study was to assess the clinical performance of a pre-fabricated zirconium dioxide implant abutment for single-tooth replacement in the posterior region.

MATERIALS AND METHODS

Forty implants of the XiVE(®) S plus screw type (DENTSPLY Friadent, Mannheim, Germany) were inserted in the posterior region of 24 patients and provided with zirconium dioxide abutments (FRIADENT(®) CERCON(®) Abutment, DENTSPLY Friadent). The following parameters were used to document the state of soft tissue: modified plaque index, modified sulcus bleeding index and pocket depth. Mesial and distal bone levels were determined on radiographs during the prosthetic treatment and at the 36-month recall.

RESULTS

Thirty-seven implants could be followed up after 36 months in function. One patient wearing two abutments was lost to follow-up. One abutment exhibited a rotational misfit after 2 years in function. A further abutment showed the same failure at the 36-months recall appointment. In the remaining 36 implants the soft and hard tissue parameters were indicative of a low inflammatory status. Compared to the baseline situation, a partly significant bone apposition could be observed. Chipping of parts of the veneering ceramic was registered in 22% of the remaining implant restorations.

CONCLUSIONS

The use of zirconia abutments in this study lead to mainly healthy peri-implant hard and soft tissue conditions but, considering the observed failures after 3 years in function, clinical long-term results should be awaited before recommending full zirconia implant abutments in a posterior indication.

摘要

目的

在过去几年中,氧化锆种植体基台在临床上得到了更广泛的应用。本研究的目的是评估一种预制二氧化锆种植体基台用于后牙单颗牙替换的临床性能。

材料与方法

将40颗XiVE(®)S Plus型螺丝种植体(德国登士柏西诺德公司,曼海姆)植入24例患者的后牙区,并安装二氧化锆基台(登士柏西诺德公司的FRIADENT(®)CERCON(®)基台)。使用以下参数记录软组织状态:改良菌斑指数、改良龈沟出血指数和牙周袋深度。在修复治疗期间及36个月复查时,通过X线片确定近中及远中骨水平。

结果

37颗种植体在功能使用36个月后可进行随访。一名佩戴两个基台的患者失访。一个基台在功能使用2年后出现旋转不匹配。在36个月复查时,另一个基台出现了同样的问题。在其余36颗种植体中,软组织和硬组织参数表明炎症状态较低。与基线情况相比,可观察到部分显著的骨附着。在其余种植体修复体中,22%出现了饰面陶瓷部分崩瓷的情况。

结论

本研究中使用氧化锆基台主要导致种植体周围软硬组织健康,但考虑到功能使用3年后观察到的失败情况,在推荐在后牙适应证中全面使用氧化锆种植体基台之前,应等待临床长期结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验