Suppr超能文献

采用高效液相色谱-串联质谱法测定尿中咖啡因及其代谢物:在人群研究中估算饮食中咖啡因的暴露量和代谢表型。

Determination of urine caffeine and its metabolites by use of high-performance liquid chromatography-tandem mass spectrometry: estimating dietary caffeine exposure and metabolic phenotyping in population studies.

机构信息

U.S. Centers for Disease Control and Prevention, National Center for Environmental Health, 4770 Buford Highway, MS F-55, Atlanta, GA, 30341, USA,

出版信息

Anal Bioanal Chem. 2014 Jan;406(3):771-84. doi: 10.1007/s00216-013-7506-9. Epub 2013 Dec 4.

Abstract

We have developed and validated a high-performance liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for determining urine caffeine and 14 caffeine metabolites suitable for estimating caffeine exposure and metabolic phenotyping in population studies. Sample preparation consisted solely of a series of simple reagent treatments at room temperature. Stable isotope-labeled analogs were used as internal standards for all analytes. We developed rapid LC-MS/MS separations for both positive and negative ion mode electrospray ionizations to maximize measurement sensitivity. Limits of detection were 0.05-0.1 μmol/L depending on the analytes. Method imprecision, based on total coefficients of variation, was generally <7 % when analyte concentration was >1 μmol/L. Analyte recoveries were typically within 10 % of being quantitative (100 %), and good agreement was observed among analytes measured across different MS/MS transitions. We applied this method to the analysis of a convenience set of human urine samples (n = 115) and were able to detect a majority of the analytes in ≥99 % of samples as well as calculate caffeine metabolite phenotyping ratios for cytochrome P450 1A2 and N-acetyltransferase 2. Whereas existing LC-MS/MS methods are limited in number of caffeine metabolites for which they are validated, or are designed for studies in which purposely elevated caffeine levels are expected, our method is the first of its kind designed specifically for the rapid, sensitive, accurate, and precise measurement of urine caffeine and caffeine metabolites at concentrations relevant to population studies.

摘要

我们开发并验证了一种高效液相色谱-串联质谱(LC-MS/MS)方法,可用于测定尿液中的咖啡因和 14 种咖啡因代谢物,适用于估计人群研究中的咖啡因暴露和代谢表型。样品制备仅包括一系列室温下的简单试剂处理。所有分析物均使用稳定同位素标记的类似物作为内标。我们开发了用于正离子模式和负离子模式电喷雾电离的快速 LC-MS/MS 分离,以最大限度地提高测量灵敏度。根据分析物的不同,检测限为 0.05-0.1 μmol/L。当分析物浓度大于 1 μmol/L 时,基于总变异系数的方法精密度通常<7%。分析物回收率通常在定量(100%)的 10%以内,并且在不同 MS/MS 跃迁中测量的分析物之间观察到良好的一致性。我们将该方法应用于一组方便的人尿液样本(n=115)的分析,能够在≥99%的样本中检测到大多数分析物,并计算细胞色素 P450 1A2 和 N-乙酰基转移酶 2 的咖啡因代谢物表型比。虽然现有的 LC-MS/MS 方法在验证的咖啡因代谢物数量上有限,或者专为预期咖啡因水平升高的研究设计,但我们的方法是第一种专门用于快速、灵敏、准确和精确测量与人群研究相关浓度的尿液咖啡因和咖啡因代谢物的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验