印度德里GTB医院地区输血中心献血者中的ABO血型不符情况。

ABO blood group discrepancies among blood donors in Regional Blood Transfusion Centre GTB Hospital, Delhi, India.

作者信息

Sharma Tanya, Garg Neeraj, Singh Bharat

机构信息

State Blood Transfusion Council, Guru Teg Bahadur Hospital, Delhi 110 095, India.

State Blood Transfusion Council, Guru Teg Bahadur Hospital, Delhi 110 095, India.

出版信息

Transfus Apher Sci. 2014 Feb;50(1):75-80. doi: 10.1016/j.transci.2013.11.002. Epub 2013 Nov 20.

Abstract

BACKGROUND

Regional Blood Transfusion Centre (RBTC), GTB Hospital, Delhi is providing safe and quality blood to one third of Delhi population. A discrepancy exists when reactions in forward grouping do not match with reverse grouping or if the previous and current results do not match.

AIM

To analyze ABO blood group discrepancies in an algorithmic manner, and to access the incidence and causes of ABO discrepancies among blood donors.

MATERIAL AND METHODS

Retrospective data of blood donors with blood group discrepancies was recorded in Regional Blood Transfusion Centre (East) Delhi, during a period of 3years from January 2010 to May 2013. DiaMed-ID Card Micro Typing System using Gel Cards (Cressier sur Morat, Switzerland) were used for determination of the ABO/Rh blood groups combined with reverse grouping. A detailed serological workup of these cases was studied for recognition and resolution of the blood group discrepancy.

RESULTS

Total number of donors during the study period were 104,010 (30,120; 31,117; 32,173 and 10,600 respectively). Blood group discrepancies were found in 51 cases (0.04%). There were 30 (58.8%) cases with low avidity anti-B Antibodies, 10 (19.6%) cases with weaker expression or subgroups of A, 2 (3.9%) cases with weaker expression or subgroups of B, 5(9.8%) cases with unexpected alloantibodies (Anti-N and Anti-M, Anti-Lea) and one(1.9%) case of Bombay blood group. In 3 cases, discrepancy could not be resolved and were referred to reference laboratory for confirmation by molecular analysis. The most frequent cause of discrepancy in forward grouping was found to be weak A or B antigen expressions and in reverse grouping decreased anti-B titers was most common.

CONCLUSION

All discrepancies reported on ABO cell and serum grouping must be investigated further, so that correct blood group is reported, minimizing the chances of transfusion reaction. A note of caution should be mentioned on the blood group card to prevent ABO incompatibility in case of transfusion.

摘要

背景

德里GTB医院的地区输血中心(RBTC)为德里三分之一的人口提供安全优质的血液。当正向定型反应与反向定型不匹配,或者之前和当前的结果不匹配时,就会出现差异。

目的

以算法方式分析ABO血型差异,并了解献血者中ABO血型差异的发生率和原因。

材料与方法

记录2010年1月至2013年5月期间德里东部地区输血中心血型存在差异的献血者的回顾性数据。使用DiaMed-ID Card微定型系统(瑞士克雷西耶-叙尔莫拉特)结合反向定型来确定ABO/Rh血型。对这些病例进行详细的血清学检查,以识别和解决血型差异问题。

结果

研究期间的献血者总数为104,010人(分别为30,120人、31,117人、32,173人和10,600人)。发现51例(0.04%)存在血型差异。其中30例(58.8%)为低亲和力抗B抗体,10例(19.6%)为A抗原表达较弱或为A亚群,2例(3.9%)为B抗原表达较弱或为B亚群,5例(9.8%)为意外同种抗体(抗N、抗M、抗Lea),1例(1.9%)为孟买血型。有3例差异无法解决,被转至参考实验室进行分子分析确认。正向定型中最常见的差异原因是A或B抗原表达较弱,反向定型中抗B效价降低最为常见。

结论

所有报告的ABO细胞和血清定型差异都必须进一步调查,以便报告正确的血型,将输血反应的可能性降至最低。应在血型卡上注明注意事项,以防止输血时出现ABO血型不合。