Suppr超能文献

在体模模型中进行实时组织弹性成像测量,并与儿科肝病患者的瞬时弹性成像进行比较。

Measurement of real-time tissue elastography in a phantom model and comparison with transient elastography in pediatric patients with liver diseases.

作者信息

Schenk Jens-Peter, Alzen Gerhard, Klingmüller Volker, Teufel Ulrike, El Sakka Saroa, Engelmann Guido, Selmi Buket

机构信息

From the Division of Pediatric Radiology (J-P.S., S.E.S., B.S. e-mail:

出版信息

Diagn Interv Radiol. 2014 Jan-Feb;20(1):90-9. doi: 10.5152/dir.2013.13116.

Abstract

PURPOSE

We aimed to determine the comparability of real-time tissue elastography (RTE) and transient elastography (TE) in pediatric patients with liver diseases.

MATERIALS AND METHODS

RTE was performed on the Elasticity QA Phantom Model 049 (Computerized Imaging Reference Systems Company Inc., Norfolk, Virginia, USA), which has five areas with different levels of stiffness. RTE measurements of relative stiffness (MEAN [mean value of tissue elasticity], AREA [% of blue color-coded stiffer tissue]) in the phantom were compared with the phantom stiffness specified in kPa (measurement unit of TE). RTE and TE were performed on 147 pediatric patients with various liver diseases. A total of 109 measurements were valid. The participants had following diseases: metabolic liver disease (n=25), cystic fibrosis (n=20), hepatopathy of unknown origin (n=11), autoimmune hepatitis (n=12), Wilson's disease (n=11), and various liver parenchyma alterations (n=30). Correlations between RTE and TE measurements in the patients were calculated. In addition, RTE was performed on a control group (n=30), and the RTE values between the patient and control groups were compared.

RESULTS

The RTE parameters showed good correlation in the phantom model with phantom stiffness (MEAN/kPa, r=-0.97; AREA/kPa, r=0.98). However, the correlation of RTE and TE was weak in the patient group (MEAN/kPa, r=-0.23; AREA/kPa, r=0.24). A significant difference was observed between the patient and control groups (MEAN, P = 5.32 e-7; AREA, P = 1.62 e-6).

CONCLUSION

In the phantom model, RTE was correlated with kPa, confirming the presumed comparability of the methods. However, there was no direct correlation between RTE and TE in patients with defined liver diseases under real clinical conditions.

摘要

目的

我们旨在确定实时组织弹性成像(RTE)和瞬时弹性成像(TE)在儿科肝病患者中的可比性。

材料与方法

在弹性质量保证体模模型049(计算机成像参考系统公司,美国弗吉尼亚州诺福克)上进行RTE检查,该体模有五个具有不同硬度水平的区域。将体模中相对硬度的RTE测量值(MEAN [组织弹性平均值],AREA [蓝色编码较硬组织的百分比])与以kPa(TE的测量单位)指定的体模硬度进行比较。对147例患有各种肝病的儿科患者进行RTE和TE检查。共有109次测量有效。参与者患有以下疾病:代谢性肝病(n = 25)、囊性纤维化(n = 20)、不明原因肝病(n = 11)、自身免疫性肝炎(n = 12)、威尔逊病(n = 11)和各种肝实质改变(n = 30)。计算患者中RTE和TE测量值之间的相关性。此外,对一个对照组(n = 30)进行RTE检查,并比较患者组和对照组之间的RTE值。

结果

RTE参数在体模模型中与体模硬度显示出良好的相关性(MEAN/kPa,r = -0.97;AREA/kPa,r = 0.98)。然而,患者组中RTE和TE的相关性较弱(MEAN/kPa,r = -0.23;AREA/kPa,r = 0.24)。患者组和对照组之间观察到显著差异(MEAN,P = 5.32×10⁻⁷;AREA,P = 1.62×10⁻⁶)。

结论

在体模模型中,RTE与kPa相关,证实了这些方法假定的可比性。然而,在实际临床条件下,明确肝病患者中RTE和TE之间没有直接相关性。