Scacciatella Paolo, Biava Lorenza Michela, Marra Sebastiano
Cardiovascular and Thoracic Diseases Department, Azienda Ospedaliera Città della Salute e della Scienza di Torino, Turin, Italy.
Catheter Cardiovasc Interv. 2014 Sep 1;84(3):494-6. doi: 10.1002/ccd.25333. Epub 2014 Jan 8.
Iatrogenic erosion of the septum primum after foramen ovale closure is an anecdotal event. We report the case of a 39-year-old woman admitted to our institution for multifocal cryptogenic cerebral ischemia and a patent foramen ovale (PFO) associated with an aneurysm of the septum primum. The patient underwent percutaneous closure of the PFO with an Amplatzer PFO Occluder device. At the 6-months follow up, the device was in the right position, but a jagged defect of the septum primum and evidence of significant left-to-right shunting was detected. The atrial septal defect was then repaired by a surgical approach. Although this event is not life-threatening, it should be considered as a therapeutic pitfall, resulting in a risk of paradoxical embolism recurrences and long-term hemodynamic impairment. © 2013 Wiley Periodicals, Inc.
卵圆孔关闭术后医源性原发隔侵蚀是一个偶发事件。我们报告了一例39岁女性,因多灶性隐源性脑缺血和与原发隔动脉瘤相关的卵圆孔未闭(PFO)入住我院。该患者接受了使用Amplatzer PFO封堵器经皮封堵PFO。在6个月的随访中,封堵器位置正确,但发现原发隔有锯齿状缺损并有明显的左向右分流迹象。随后通过手术方法修复了房间隔缺损。虽然这一事件不会危及生命,但应将其视为治疗中的一个陷阱,会导致反常栓塞复发和长期血流动力学损害的风险。© 2013威利期刊公司