• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Evaluation of the latex turbidimetric immunoassay for CK-MB protein].

作者信息

Okubo Manabu, Kimura Shigeki, Matsui Masahiko, Suehisa Etsuji, Hidaka Yoh

机构信息

Division of Clinical Laboratory, Department of Medical Technology, Osaka University Hospital, Suita 565-0871, Japan.

出版信息

Rinsho Byori. 2013 Nov;61(11):989-94.

PMID:24450103
Abstract

CK-MB protein is an important marker for the diagnosis of acute coronary syndromes. In the present study, we evaluated the basal performance of recently developed CK-MB mass kit "L-type wako CK-MB mass". Within-run and between-day precision were obtained with 1.4-4.7% and 2.7-5.2%, respectively. Diluted linearity and lower limit of detection were obtained with 180.0 ng/mL and 2.1 ng/mL, respectively. Zone phenomenon was able to detect until 25,600.0 ng/mL. Analysis of interferent showed that only CK-BB positively influenced the assay results. CK-MB protein levels decreased to 82% at 72 hours in the room temperature, but it was stable at 4 degrees C and -20 degrees C. The correlation coefficient(r) between this assay and conventional assay was 0.999. However, discrepancy of the two cases was observed in the comparison between the two methods. In the case 1, CK isoenzyme analysis using electrophoresis indicated that CK-MB was not present and absorption test showed a 68% absorption effect of CK-MB protein values not by anti human IgG, anti human IgA, and animal serums, but anti human IgM. In the case 2, CK isoenzyme analysis indicated that there is not only CK-MB but CK-BB. CK-MB protein values between the two methods were fitted after decreasing CK-BB. Thus, Value discrepancy for CK-MB protein was resulting from IgM and CK-BB. We have to pay attention to such phenomenon when detecting an unlikely higher levels that could not be explained by clinical information.

摘要

相似文献

1
[Evaluation of the latex turbidimetric immunoassay for CK-MB protein].
Rinsho Byori. 2013 Nov;61(11):989-94.
2
[Clinical evaluation of the new creatine kinase MB reagent kit "L-System CK-MB MtO"].
Rinsho Byori. 2011 Mar;59(3):236-42.
3
[Evaluation of the Creatine Kinase MB Activity Assay Kit].
Rinsho Byori. 2014 Nov;62(11):1040-6.
4
Development and Evaluation of a New Creatine Kinase MB Mass Determination Assay Using a Latex Agglutination Turbidimetric Immunoassay with an Automated Analyzer.
Clin Lab. 2016;62(5):877-85. doi: 10.7754/clin.lab.2015.150910.
5
Development and performance of an enzyme immunoassay to detect creatine kinase isoenzyme MB activity using anti-mitochondrial creatine kinase monoclonal antibodies.使用抗线粒体肌酸激酶单克隆抗体检测肌酸激酶同工酶MB活性的酶免疫测定法的开发与性能
Scand J Clin Lab Invest. 2009;69(6):687-95. doi: 10.3109/00365510902981171.
6
[Establishment of a cut-off value for the diagnosis of acute myocardial infarction using a new CK-MB activity measurement reagent containing anti-MtCK antibody].
Rinsho Byori. 2011 Jul;59(7):649-55.
7
Analytical performance of time-resolved fluorometry-based Innotrac Aio! cardiac marker immunoassays.基于时间分辨荧光法的Innotrac Aio!心脏标志物免疫分析的分析性能。
Scand J Clin Lab Invest. 2003;63(1):55-64. doi: 10.1080/00365510310000493.
8
Evaluation of the chemiluminescence immunoassays for the measurement of troponin I, myoglobin and CK-MB using the IMMULITE system in comparison to other measuring systems.使用IMMULITE系统与其他测量系统相比,对用于测量肌钙蛋白I、肌红蛋白和肌酸激酶同工酶MB的化学发光免疫分析进行评估。
Clin Lab. 2002;48(3-4):211-21.
9
Quantifying the MB isoenzyme of creatine kinase with the Abbott "IMx" immunoassay analyzer.使用雅培“IMx”免疫分析分析仪对肌酸激酶的MB同工酶进行定量分析。
Clin Chem. 1990 Feb;36(2):375-8.
10
Evaluation of a point-of-care assay for cardiac markers for patients suspected of acute myocardial infarction.对疑似急性心肌梗死患者进行心脏标志物即时检测分析的评估。
Clin Chim Acta. 2004 Aug 16;346(2):211-9. doi: 10.1016/j.cccn.2004.03.036.