Suppr超能文献

全细胞钳制豚鼠心脏细胞中慢反应的最大反应速度(Vmax)与钙电流可用性之间的关系

On the relationship between V max of slow responses and Ca-current availability in whole-cell clamped guinea pig heart cells.

作者信息

Malécot C O, Trautwein W

机构信息

II. Physiologisches Institut Universität des Saarlandes, Homburg/Saar, Federal Republic of Germany.

出版信息

Pflugers Arch. 1987 Sep;410(1-2):15-22. doi: 10.1007/BF00581890.

Abstract

The relationship between Ca current availability and maximum rate of rise (V max) of slow responses was determined in the same single guinea pig ventricular heart cell under voltage and current clamp conditions (whole-cell clamp technique). The results are as follows. (1) Cell capacitance measured in 32 cells from the current response to a fast ramp voltage-clamp pulse (119.6 +/- 4.6 pF, mean +/- SE) or from Vmax values at a holding potential of -50 or -40 mV (118.6 +/- 5.3 pF) are identical. (2) In control conditions ([Ca]o 1.8, [K]o 4 and [Cs]i 140 mM), voltage-dependence of steady-state inactivation of Ca current (ICa) or Vmax are similar up to -35 mV. However, Vmax significantly (P less than 0.005) underestimates ICa availability at more positive potentials. At -30 mV, ICa and Vmax amplitudes represent respectively 35.6 and 22.4% (n = 14) of their maximum value. (3) In the presence of 50 nM isoprenaline, Vmax and the underlying ICa are respectively increased by 79.2 +/- 13.8% and 71.2 +/- 13.8% (n = 15). No statistically significant deviation from linearity is then observed. (4) When Vmax amplitude is expressed as a function of ICa density, an almost linear relationship is observed for Vmax values between 0 and 25 V/s. Vmax is then best described by the equation: Vmax (V/s) = 1.043 ICa (pA/pF) -0.514 (46 cells). (5) We conclude that, under conditions that minimize outward currents, Vmax of slow responses accurately measures ICa amplitude, except when ICa is decreased to less than 40% of its maximum control amplitude (i.e., below 4 pA/pF). At that point, Vmax underestimates ICa.

摘要

在电压钳和电流钳条件下(全细胞钳技术),于同一只豚鼠心室肌单个细胞中测定钙电流有效性与慢反应最大上升速率(Vmax)之间的关系。结果如下:(1)从快速斜坡电压钳脉冲的电流响应(119.6±4.6 pF,均值±标准误)或在-50或-40 mV的钳制电位下的Vmax值测得的32个细胞的细胞电容(118.6±5.3 pF)相同。(2)在对照条件下([Ca]o 1.8、[K]o 4和[Cs]i 140 mM),钙电流(ICa)稳态失活或Vmax的电压依赖性在-35 mV之前相似。然而,在更正的电位下,Vmax显著(P<0.005)低估了ICa有效性。在-30 mV时,ICa和Vmax幅度分别为其最大值的35.6%和22.4%(n = 14)。(3)在存在50 nM异丙肾上腺素的情况下,Vmax和基础ICa分别增加79.2±13.8%和71.2±13.8%(n = 15)。未观察到统计学上显著的线性偏差。(4)当Vmax幅度表示为ICa密度的函数时,在0至25 V/s之间的Vmax值观察到几乎呈线性关系。然后,Vmax最好用以下方程描述:Vmax(V/s)= 1.043 ICa(pA/pF)-0.514(46个细胞)。(5)我们得出结论,在使外向电流最小化的条件下,慢反应的Vmax准确测量ICa幅度,除非ICa降低至其最大对照幅度的40%以下(即低于4 pA/pF)。此时,Vmax低估了ICa。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验