Visualization of joint and bone using dual-energy CT arthrography with contrast subtraction: in vitro feasibility study using porcine joints.

作者信息

Chai Jee Won, Choi Jung-Ah, Choi Ja-Young, Kim Sujin, Hong Sung Hwan, Kang Heung Sik

机构信息

Department of Radiology, SMG-SNU Boramae Medical Center, 425 Shindaebang-dong, Dongjak-gu, Seoul, 156-707, Republic of Korea.

出版信息

Skeletal Radiol. 2014 May;43(5):673-8. doi: 10.1007/s00256-014-1817-6. Epub 2014 Jan 25.

Abstract

OBJECTIVE

To assess the feasibility of subtracting various concentrations of iodinated contrast material on dual-energy computed tomographic (DECT) arthrography to provide both CT arthrography and virtual unenhanced CT (VUCT) in a single CT acquisition.

MATERIALS AND METHODS

This was an in vitro study for which institutional review board approval was not required. CT arthrographies of 12 joints of pig cadavers were obtained using dual-energy CT. Various concentrations of iodinated contrast material, 25% (75 mg/ml), 50% (150 mg/ml), 75% (225 mg/ml), and 100% (300 mg/ml) were used for the DECT arthrography. The paired regions of interest (ROI) were drawn over the same location on two paired CT scans at different tube voltages (80 kVp and 140 kVp). The average Hounsfield units (HU) ratio of the contrast media(HU on CT at 80 kVp/HU on CT at 140 kVp) was calculated for each joint. Subtraction of contrast material was carried out using VUCT application

RESULTS

The 25% iodinated contrast mixture was successfully subtracted from DECT arthrography of four joints, in which the average HU ratio ranged from 1.95 to 2.0. The subtraction of the 50%,75%, and 100% iodine contrast mixtures was not successful, because of the upper demonstrable HU limit in dual-energy CT.

CONCLUSIONS

DECT arthrography with 25% iodinated contrast medium injection can provide both CT arthrography and virtual unenhanced images in a single CT acquisition.

摘要

目的

评估在双能计算机断层扫描(DECT)关节造影中减去不同浓度碘对比剂的可行性,以便在一次CT采集中同时获得CT关节造影和虚拟平扫CT(VUCT)图像。

材料与方法

本研究为体外研究,无需机构审查委员会批准。使用双能CT对猪尸体的12个关节进行CT关节造影。在DECT关节造影中使用了不同浓度的碘对比剂,分别为25%(75mg/ml)、50%(150mg/ml)、75%(225mg/ml)和100%(300mg/ml)。在不同管电压(80kVp和140kVp)下的两组配对CT扫描的相同位置绘制配对感兴趣区(ROI)。计算每个关节对比剂的平均亨氏单位(HU)比值(80kVp时CT上的HU/140kVp时CT上的HU)。使用VUCT应用程序减去对比剂。

结果

在四个关节的DECT关节造影中成功减去了25%的碘对比剂混合物,其平均HU比值范围为1.95至2.0。由于双能CT中可显示的HU上限,50%、75%和100%碘对比剂混合物的减法不成功。

结论

注射25%碘对比剂的DECT关节造影可在一次CT采集中同时提供CT关节造影和虚拟平扫图像。