J Fluoresc. 2014 May;24(3):787-93. doi: 10.1007/s10895-014-1352-9. Epub 2014 Feb 4.
A novel method could be adopted successfully for determination of anthracene in environmental samples, utilizing dispersive liquid-liquid extraction followed by first-derivative synchronous fluorimetry at a constant wavelength difference Δλ = 165 nm, where a linear calibration curve was obtained in a concentration range of 0.5-100 ng mL(-1) at 244 nm. The detection limit was 0.1 ng mL(-1). The method can be easily adopted for determination of anthracene in aqueous media including tap water and river water. The recoveries obtained were 85.40-108.02%. The proposed method was validated according to International Conference of Harmonization (ICH) guide lines and successfully applied to determine anthracene in pure form and in water samples including real life water samples from different sources. All the results obtained were compared with those of published method, where no a significant difference was observed.
一种新方法可成功用于环境样品中蒽的测定,该方法采用分散液液萃取,随后在恒定波长差Δλ = 165 nm处进行一阶导数同步荧光法测定,在244 nm处,浓度范围为0.5 - 100 ng mL(-1)时可获得线性校准曲线。检测限为0.1 ng mL(-1)。该方法可轻松用于测定包括自来水和河水在内的水性介质中的蒽。回收率为85.40 - 108.02%。所提出的方法根据国际协调会议(ICH)指南进行了验证,并成功应用于测定纯形式的蒽以及包括来自不同来源的实际水样在内的水样中的蒽。将所有获得的结果与已发表方法的结果进行比较,未观察到显著差异。