Dave Utsav D, Uvin Sarah, Kuyken Bart, Selvaraja Shankar, Leo Francois, Roelkens Gunther
Opt Express. 2013 Dec 30;21(26):32032-9. doi: 10.1364/OE.21.032032.
A 1,000 nm wide supercontinuum, spanning from 1470 nm in the telecom band to 2470 nm in the mid-infrared is demonstrated in a 800 nm x 220 nm 1 cm long hydrogenated amorphous silicon strip waveguide. The pump source was a picosecond Thulium doped fiber laser centered at 1950 nm. The real part of the nonlinear parameter of this waveguide at 1950 nm is measured to be 100 ± 10 W -1m-1, while the imaginary part of the nonlinear parameter is measured to be 1.2 ± 0.2 W-1m-1. The supercontinuum is stable over a period of at least several hours, as the hydrogenated amorphous silicon waveguides do not degrade when exposed to the high power picosecond pulse train.
在一条800纳米×220纳米、长1厘米的氢化非晶硅条形波导中,展示出了一个宽度为1000纳米的超连续谱,其范围从电信波段的1470纳米延伸至中红外波段的2470纳米。泵浦源是一个中心波长为1950纳米的皮秒掺铥光纤激光器。该波导在1950纳米处非线性参数的实部测量值为100±10瓦-1米-1,而非线性参数的虚部测量值为1.2±0.2瓦-1米-1。由于氢化非晶硅波导在暴露于高功率皮秒脉冲序列时不会退化,因此超连续谱在至少几个小时的时间段内是稳定的。