Suppr超能文献

正常猫的微剂量计算机断层扫描心脏血管造影术。

Microdose computed tomographic cardiac angiography in normal cats.

作者信息

Rodriguez Kiira T, O'Brien Mauria A, Hartman Susan K, Mulherin Allison C, McReynolds Casie J, McMichael Maureen, Rapoport Gregg, O'Brien Robert T

机构信息

Department of Veterinary Clinical Medicine, University of Illinois at Urbana-Champaign, 1008 W. Hazelwood Dr., Urbana, IL 61802, USA.

Department of Small Animal Medicine and Surgery, University of Georgia, 501 D.W. Brooks Dr., Athens, GA 30602, USA.

出版信息

J Vet Cardiol. 2014 Mar;16(1):19-25. doi: 10.1016/j.jvc.2013.12.004. Epub 2014 Jan 16.

Abstract

OBJECTIVES

To determine if microdose contrast-enhanced multi-detector computed tomographic angiography (MDCTA) allows characterization of cardiac chambers in lightly sedated normal cats.

ANIMALS

Seven healthy domestic cats.

METHODS

Lightly sedated normal cats were imaged pre-contrast and with microdose (0.22 ml/kg of non-ionic iodinated contrast medium, 300 mg I/ml) triple-phase MDCTA in a motion restriction device.

RESULTS

On pre-contrast images, the aorta (median: 52.43 Hounsfield units [HU], range 27.35-76.74 HU) was outlined by significantly (p = 0.015) lower attenuating periaortic fat (-66.16 HU, -42.62 to -92.77 HU). On post-contrast images, median peak contrast enhancement in the right ventricle (111.77 HU, 36.09-141.60 HU) was achieved in 3.1 s (range 2.9-7.3 s), in the aorta (149.30 HU, 99.43-319.60 HU) and left atrium (180.83 HU, 88.53-266.84 HU) in 6.4 s (range 5.6-7.7 s) and in the left ventricle (147.89 HU, 57.23-245.77 HU) in 7.10 s (range 6.2-11.2 s). Significantly higher attenuation was measured between all chambers and walls, the right ventricular lumen and interventricular septum (median ratio 53.78 HU, range 0.21-83.20 HU), left ventricular lumen and left ventricular free wall (89.32 HU, 38.81-185.95 HU) and aorta and periaortic fat (190.43 HU, 143.22-425.44 HU) on post-contrast images.

CONCLUSIONS

Sufficient biological contrast is available on survey CT to discriminate between the aorta and the left atrium, and microdose MDCTA provides sufficient contrast enhancement for adequate visualization of the heart chambers in normal cats.

摘要

目的

确定微剂量对比增强多层螺旋计算机断层血管造影(MDCTA)是否能够在轻度镇静的正常猫中对心腔进行特征性描述。

动物

7只健康家猫。

方法

在运动限制装置中,对轻度镇静的正常猫在注射对比剂前以及注射微剂量(0.22 ml/kg非离子型碘化对比剂,300 mg I/ml)进行三相MDCTA时进行成像。

结果

在注射对比剂前的图像上,主动脉(中位数:52.43亨氏单位[HU],范围27.35 - 76.74 HU)被主动脉周围脂肪(-66.16 HU,-42.62至-92.77 HU)显著(p = 0.015)低衰减勾勒出轮廓。在注射对比剂后的图像上,右心室的中位数峰值对比增强(111.77 HU,36.09 - 141.60 HU)在3.1秒(范围2.9 - 7.3秒)时达到,主动脉(149.30 HU,99.43 - 319.60 HU)和左心房(180.83 HU,88.53 - 266.84 HU)在6.4秒(范围5.6 - 7.7秒)时达到,左心室(147.89 HU,57.23 - 245.77 HU)在7.10秒(范围6.2 - 11.2秒)时达到。在注射对比剂后的图像上,所有心腔与心肌壁、右心室腔与室间隔(中位数比值53.78 HU,范围0.21 - 83.20 HU)、左心室腔与左心室游离壁(89.32 HU,38.81 - 185.95 HU)以及主动脉与主动脉周围脂肪(190.43 HU,143.22 - 425.44 HU)之间测量到显著更高的衰减。

结论

在平扫CT上有足够的生物对比来区分主动脉和左心房,并且微剂量MDCTA提供了足够的对比增强,以充分显示正常猫的心腔。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验