Suppr超能文献

钇稳定四方氧化锆的表面处理及粘结剂类型对人工老化后全冠固位力的影响。

Influence of surface treatment of yttrium-stabilized tetragonal zirconium oxides and cement type on crown retention after artificial aging.

作者信息

Karimipour-Saryazdi Mehdi, Sadid-Zadeh Ramtin, Givan Daniel, Burgess John O, Ramp Lance C, Liu Perng-Ru

机构信息

Resident, Department of Restorative Sciences, School of Dentistry University of Alabama at Birmingham, Birmingham, Ala.

Assistant Professor, Department of Restorative Sciences, University at Buffalo School of Dental Medicine, Buffalo, NY.

出版信息

J Prosthet Dent. 2014 May;111(5):395-403. doi: 10.1016/j.prosdent.2013.09.034. Epub 2014 Feb 14.

Abstract

STATEMENT OF PROBLEM

Information about the influence of zirconia crown surface treatment and cement type on the retention of zirconia crowns is limited. It is unclear whether zirconia crowns require surface treatment to enhance their retention.

PURPOSE

The purpose of this in vitro study was to evaluate the effect of surface treatment on the retention of zirconia crowns cemented with 3 different adhesive resin cements after artificial aging.

MATERIAL AND METHODS

Ninety extracted human molars were prepared for ceramic crowns (approximately 20-degree taper, approximately 4-mm axial length) and were divided into 3 groups (n=30). Computer-aided design and computer-aided manufacturing zirconia copings were fabricated. Three surface treatments were applied to the intaglio surface of the copings. The control group received no treatment, the second group was airborne-particle abraded with 50 μm Al2O3, and the third group was treated with 30 μm silica-modified Al2O3, The copings were luted with a self-etch (RelyX Unicem 2), a total-etch (Duo-Link), or a self-etch primer (Panavia F 2.0) adhesive cement. They were stored for 24 hours at 37°C before being artificially aged with 5000 (5°C-55°C) thermal cycles and 100,000 cycles of 70 N dynamic loading. Retention was measured on a universal testing machine under tension, with a crosshead speed of 0.5 mm/min. Statistical analysis was performed with 1-way and 2-way ANOVA.

RESULTS

Mean retention values ranged from 0.72 to 3.7 MPa. Surface treatment increased crown retention, but the difference was not statistically significant (P>.05), except for the Duo-Link cement group (P<.05). Analysis of the adhesives revealed that the Duo-Link cement resulted in significantly lower crown retention (P<.05) than the other 2 cements.

CONCLUSION

For zirconia crowns, retention seems to be dependent on cement type rather than surface treatment.

摘要

问题陈述

关于氧化锆全冠表面处理及粘结剂类型对氧化锆全冠固位力影响的相关信息有限。目前尚不清楚氧化锆全冠是否需要进行表面处理以增强其固位力。

目的

本体外研究的目的是评估人工老化后表面处理对用3种不同粘结树脂水门汀粘结的氧化锆全冠固位力的影响。

材料与方法

90颗拔除的人磨牙预备成陶瓷全冠(锥度约20°,轴长约4mm),并分为3组(n = 30)。制作计算机辅助设计和计算机辅助制造的氧化锆基底冠。对基底冠的内表面进行3种表面处理。对照组未处理,第二组用50μm Al2O3进行空气颗粒喷砂处理,第三组用30μm二氧化硅改性的Al2O3处理。基底冠分别用自酸蚀粘结剂(RelyX Unicem 2)、全酸蚀粘结剂(Duo-Link)或自酸蚀底漆粘结剂(Panavia F 2.0)粘结。在37°C下储存24小时后,再进行5000次(5°C - 55°C)热循环和100,000次70N动态加载的人工老化处理。在万能试验机上以0.5mm/min的十字头速度进行拉伸试验,测量固位力。采用单因素和双因素方差分析进行统计学分析。

结果

平均固位力值范围为0.72至3.7MPa。表面处理增加了全冠的固位力,但差异无统计学意义(P >.05),Duo-Link粘结剂组除外(P <.05)。对粘结剂的分析显示,Duo-Link粘结剂导致的全冠固位力显著低于其他2种粘结剂(P <.05)。

结论

对于氧化锆全冠,固位力似乎取决于粘结剂类型而非表面处理。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验