Loh Tze Ling, Chin Ronald, Flynn Peter, Jayachandra Shruti
Nepean Hospital, Kingswood, New South Wales, Australia.
BMJ Case Rep. 2014 Feb 19;2014:bcr2013203232. doi: 10.1136/bcr-2013-203232.
A 70-year-old woman presented with a fracture and aspiration of her polyvinyl chloride tracheostomy tube. Her chest X-ray showed that a foreign body was lodged in the right main bronchus. She was otherwise asymptomatic. The foreign body was removed under general anaesthesia using a flexible bronchoscope. The patient developed pneumonia after the procedure and was admitted to the intensive care unit. She was discharged home 5 days after the event with no permanent complications.
一名70岁女性因聚氯乙烯气管造口管骨折并吸入异物前来就诊。她的胸部X光显示有一个异物卡在右主支气管内。除此之外,她没有其他症状。在全身麻醉下,通过可弯曲支气管镜取出了异物。术后患者发生了肺炎,并被收入重症监护病房。事件发生5天后,她出院回家,没有留下永久性并发症。