Mishra Tulsidas, Shrivastav Pranav S
Chemistry Department, Kadi Sarva Vishwavidyalaya, Gandhinagar 382015, India.
Department of Chemistry, School of Sciences, Gujarat University, Ahmedabad 380009, India.
ScientificWorldJournal. 2014 Jan 23;2014:482693. doi: 10.1155/2014/482693. eCollection 2014.
HIV protease inhibitors are used in the treatment of patients suffering from AIDS and they act at the final stage of viral replication by interfering with the HIV protease enzyme. The paper describes a selective, sensitive, and robust method for simultaneous determination of three protease inhibitors atazanavir, darunavir and ritonavir in human plasma by ultra performance liquid chromatography-tandem mass spectrometry.
The sample pretreatment consisted of solid phase extraction of analytes and their deuterated analogs as internal standards from 50 μL human plasma. Chromatographic separation of analytes was performed on Waters Acquity UPLC C18 (50 × 2.1 mm, 1.7 μm) column under gradient conditions using 10 mM ammonium formate, pH 4.0, and acetonitrile as the mobile phase.
The method was established over a concentration range of 5.0-6000 ng/mL for atazanavir, 5.0-5000 ng/mL for darunavir and 1.0-500 ng/mL for ritonavir. Accuracy, precision, matrix effect, recovery, and stability of the analytes were evaluated as per US FDA guidelines.
The efficiency of sample preparation, short analysis time, and high selectivity permit simultaneous estimation of these inhibitors. The validated method can be useful in determining plasma concentration of these protease inhibitors for therapeutic drug monitoring and in high throughput clinical studies.
HIV蛋白酶抑制剂用于治疗艾滋病患者,它们通过干扰HIV蛋白酶在病毒复制的最后阶段发挥作用。本文描述了一种采用超高效液相色谱 - 串联质谱法同时测定人血浆中三种蛋白酶抑制剂阿扎那韦、达芦那韦和利托那韦的选择性、灵敏且稳健的方法。
样品预处理包括从50μL人血浆中通过固相萃取分析物及其作为内标的氘代类似物。使用10 mM甲酸铵(pH 4.0)和乙腈作为流动相,在梯度条件下于Waters Acquity UPLC C18(50×2.1 mm,1.7μm)柱上对分析物进行色谱分离。
该方法对阿扎那韦的测定浓度范围为5.0 - 6000 ng/mL,对达芦那韦为5.0 - 5000 ng/mL,对利托那韦为1.0 - 500 ng/mL。按照美国食品药品监督管理局(US FDA)指南评估了分析物的准确度、精密度、基质效应、回收率和稳定性。
样品制备效率高、分析时间短且选择性高,可同时测定这些抑制剂。经验证的方法可用于测定这些蛋白酶抑制剂的血浆浓度,以进行治疗药物监测和高通量临床研究。