Donnelly Ryan F, Mooney Karen, McCrudden Maelíosa T C, Vicente-Pérez Eva M, Belaid Luc, González-Vázquez Patricia, McElnay James C, Woolfson A David
School of Pharmacy, Queen's University Belfast, Belfast, BT9 7BL, UK.
J Pharm Sci. 2014 May;103(5):1478-86. doi: 10.1002/jps.23921. Epub 2014 Mar 14.
We describe, for the first time, quantification of in-skin swelling and fluid uptake by hydrogel-forming microneedle (MN) arrays and skin barrier recovery in human volunteers. Such MN arrays, prepared from aqueous blends of hydrolyzed poly(methylvinylether/maleic anhydride) (15%, w/w) and the cross-linker poly(ethyleneglycol) 10,000 Da (7.5%, w/w), were inserted into the skin of human volunteers (n = 15) to depths of approximately 300 μm by gentle hand pressure. The MN arrays swelled in skin, taking up skin interstitial fluid, such that their mass had increased by approximately 30% after 6 h in skin. Importantly, however, skin barrier function recovered within 24 h after MN removal, regardless of how long the MN had been in skin or how much their volume had increased with swelling. Further research on closure of MN-induced micropores is required because transepidermal water loss measurements suggested micropore closure, whereas optical coherence tomography indicated that MN-induced micropores had not closed over, even 24 h after MN had been removed. There were no complaints of skin reactions, adverse events, or strong views against MN use by any of the volunteers. Only some minor erythema was noted after patch removal, although this always resolved within 48 h, and no adverse events were present on follow-up.
我们首次描述了对形成水凝胶的微针(MN)阵列在人体皮肤内的肿胀、液体吸收情况以及皮肤屏障恢复情况的量化。这种MN阵列由水解聚(甲基乙烯基醚/马来酸酐)(15%,w/w)和交联剂聚乙二醇10,000 Da(7.5%,w/w)的水性混合物制备而成,通过轻轻手动施压将其插入15名人体志愿者的皮肤中,深度约为300μm。MN阵列在皮肤中肿胀,吸收皮肤间质液,以至于在皮肤中放置6小时后其质量增加了约30%。然而,重要的是,无论MN在皮肤中放置了多长时间或其因肿胀而体积增加了多少,在移除MN后24小时内皮肤屏障功能均可恢复。由于经表皮水分流失测量表明微针诱导的微孔已闭合,而光学相干断层扫描显示即使在移除MN后24小时,MN诱导的微孔仍未完全闭合,因此需要对MN诱导的微孔闭合进行进一步研究。没有任何志愿者抱怨皮肤反应、不良事件或强烈反对使用MN。移除贴片后仅观察到一些轻微红斑,不过这些红斑总是在48小时内消退,随访时未出现不良事件。