Brin Y S, Palmanovich E, Aliev E, Laver L, Yaacobi E, Nyska M, Kish B J
Department of Orthopaedic Surgery, Meir Medical Center, Kfar-Saba, Tel-Aviv University, Israel.
Department of Orthopaedic Surgery, Meir Medical Center, Kfar-Saba, Tel-Aviv University, Israel.
Injury. 2014 Jul;45(7):1071-5. doi: 10.1016/j.injury.2014.02.022. Epub 2014 Feb 23.
The purpose of the study was to assess whether using two fluoroscopes simultaneously in closed reduction and internal fixation of a stable intertrochanteric fracture reduces radiation and operation time. Patients who sustained a stable intertrochanteric femoral fracture were operated in our institution with closed reduction and internal fixation. They were randomly allocated to be operated with the assistance of one or two fluoroscopes. With one device, the radiology technician controlled and moved it to the desired anterior-posterior or axial view. With two fluoroscopes, one was positioned in the anterior-posterior view and the other in the axial view, both controlled by the surgeon. Total radiation and operation time were collected for all patients and compared between the two groups. A total of 27 patients participated in the study. One fluoroscope was used for 13 surgeries and two in 14. Total radiation time was shorter with two fluoroscopes compared to the use of one (36.6±8.6s versus 51.2±18.9s, respectively; p<0.02), as was total operation time (24.3±4.2min and 34.7±11.9min, respectively; p<0.01). Working simultaneously with two fluoroscopic devices is safer for the medical team in the operating theatre, because it decreases the patient's radiation exposure, wound exposure time, and anaesthesia time. It saves operating room time and fluoroscopy personnel during the operation. When operating on hip fractures that are planned to be reduced and fixated, we recommend working with two fluoroscopes simultaneously.
本研究的目的是评估在稳定型股骨转子间骨折的闭合复位内固定术中同时使用两个荧光透视仪是否能减少辐射和手术时间。在我们机构中,对发生稳定型股骨转子间骨折的患者进行了闭合复位内固定手术。他们被随机分配在一个或两个荧光透视仪的辅助下进行手术。使用一个设备时,放射技术人员控制并将其移动到所需的前后位或轴位视图。使用两个荧光透视仪时,一个置于前后位视图,另一个置于轴位视图,均由外科医生控制。收集所有患者的总辐射时间和手术时间,并在两组之间进行比较。共有27名患者参与了该研究。13例手术使用了一个荧光透视仪,14例使用了两个。与使用一个荧光透视仪相比,使用两个荧光透视仪时的总辐射时间更短(分别为36.6±8.6秒和51.2±18.9秒;p<0.02),总手术时间也是如此(分别为24.3±4.2分钟和34.7±11.9分钟;p<0.01)。在手术室中,医疗团队同时使用两个荧光透视设备工作更安全,因为它减少了患者的辐射暴露、伤口暴露时间和麻醉时间。它在手术过程中节省了手术室时间和荧光透视人员。在对计划进行复位和固定的髋部骨折进行手术时,我们建议同时使用两个荧光透视仪。