Suppr超能文献

太空发现:全颜面移植体在六个自由度上的计算机辅助正颌对齐

Found in space: computer-assisted orthognathic alignment of a total face allograft in six degrees of freedom.

作者信息

Dorafshar Amir H, Brazio Philip S, Mundinger Gerhard S, Mohan Raja, Brown Emile N, Rodriguez Eduardo D

机构信息

Assistant Professor, Division of Plastic and Reconstructive Surgery, R Adams Cowley Shock Trauma Center, University of Maryland Medical Center, Baltimore, MD.

Resident, Department of Surgery, University of Maryland Medical Center, Baltimore, MD.

出版信息

J Oral Maxillofac Surg. 2014 Sep;72(9):1788-800. doi: 10.1016/j.joms.2014.01.016. Epub 2014 Jan 31.

Abstract

PURPOSE

Full facial osteomyocutaneous transplantation requires correct 3-dimensional (3D) alignment of donor osseous structures to a new cranial base with minimal reference points and 6 degrees of potential movement. We investigated whether computer-assisted design and manufacturing (CAD/CAM) could enable accurate placement of the facial skeleton.

MATERIALS AND METHODS

A prospective single-cohort study of Le Fort III-based maxillary-mandibular segment allotransplantation was performed in 5 cadaver pairs and 1 clinical pair. The osteotomies were modeled using computed tomography (CT) data and 3D modeling software and then translated to the donor-recipient pairs using surgical navigation and osteotomy cutting guides. The predicted values were calculated about all rotational axes (pitch, yaw, and roll) and along all translational axes (vertical, horizontal, and anteroposterior) and used as the independent variable. The primary outcome variable of the actual postoperative CT values was compared for fidelity to the prediction using the intraclass correlation coefficient (ICC). The similarity to the donor versus recipient values was calculated as a secondary independent variable, and both predicted and actual measurements were compared with it as a percentage.

RESULTS

The postoperative fidelity to the plan was adequate to excellent (ICC 0.520 to 0.975) with the exception of lateral translation (2.94 ± 1.31 mm predicted left vs 3.92 ± 2.17 mm right actual displacement; ICC 0.243). The predicted and actual values were not consistently skewed toward the donor or recipient values.

CONCLUSIONS

We have demonstrated a novel application of CAD/CAM that enables orthognathic alignment of a maxillary-mandibular segment to a new cranial base. Quantification of the alignment in all 6 degrees of freedom delivers precise control compared with the planned changes and allows postoperative quality control.

摘要

目的

全颜面骨肌皮瓣移植需要将供体骨结构精确地三维(3D)对齐到新的颅底,参考点最少且有6个潜在的移动自由度。我们研究了计算机辅助设计与制造(CAD/CAM)是否能实现面部骨骼的精确放置。

材料与方法

对5对尸体和1对临床病例进行了基于Le Fort III型的上颌-下颌节段同种异体移植的前瞻性单队列研究。使用计算机断层扫描(CT)数据和3D建模软件对上颌骨切开术进行建模,然后通过手术导航和截骨切割导板将其应用于供体-受体对。计算所有旋转轴(俯仰、偏航和滚动)以及所有平移轴(垂直、水平和前后)的预测值,并将其用作自变量。使用组内相关系数(ICC)比较实际术后CT值这一主要结局变量与预测值的符合程度。计算供体与受体值的相似性作为次要自变量,并将预测测量值和实际测量值与其进行百分比比较。

结果

除横向平移外,术后与计划的符合程度为良好至优秀(ICC为0.520至0.975)(预测左侧横向平移2.94±1.31mm,实际右侧移位3.92±2.17mm;ICC为0.243)。预测值和实际值并不总是偏向供体或受体值。

结论

我们展示了CAD/CAM的一种新应用,它能够将上颌-下颌节段与新的颅底进行正颌对齐。与计划的变化相比,对所有6个自由度的对齐进行量化可实现精确控制,并允许进行术后质量控制。