Devreese Mathias, Maes An, De Baere Siegrid, De Backer Patrick, Croubels Siska
Department of Pharmacology, Toxicology and Biochemistry, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, B-9820 Merelbeke, Belgium.
J Chromatogr A. 2014 Aug 1;1353:106-13. doi: 10.1016/j.chroma.2014.02.090. Epub 2014 Mar 12.
A specific and sensitive LC-MS/MS method was developed for quantitative determination of closantel in bovine and ovine colostrum and tank milk. Sample preparation consisted of extracting milk samples with acetonitrile/acetone (80/20, v/v) followed by SPE clean-up with Oasis mixed anion exchange columns. After elution with 5% formic acid in acetonitrile and evaporation to dryness, the residue was reconstituted in acetonitrile and water. HPLC separation was achieved on a Zorbax Eclipse Plus C18 column and a gradient elution program with 1mM ammonium acetate in water and acetonitrile. For closantel determination in bovine milk, the method was validated according to EU Volume 8 guidelines whereas for ovine milk both EU Volume 8 and VICH GL49 criteria were applied. The linear range of the method is between 10 and 2000 μg/kg, the limit of quantification 10 μg/kg and limit of detection is 0.63 and 0.32 μg/kg for sheep colostrum and tank milk and 1.27 and 1.24 μg/kg for cattle colostrum and tank milk, respectively. Both guidelines cover a similar set of parameters (linearity, accuracy, precision, limit of detection and limit of quantification), although the acceptance criteria might differ (accuracy and precision) or no specific acceptability ranges are specified in neither guidelines (LOD and LOQ). For some parameters, only one of the guidelines indicates acceptance criteria: EU Volume 8 for applicability, practicability and susceptibility and VICH GL 49 for linearity, specificity and analyte stability.
建立了一种特异且灵敏的液相色谱-串联质谱法(LC-MS/MS),用于定量测定牛初乳、羊初乳及罐装牛奶中的氯氰碘柳胺。样品制备包括用乙腈/丙酮(80/20,v/v)提取牛奶样品,随后用Oasis混合阴离子交换柱进行固相萃取净化。用含5%甲酸的乙腈洗脱并蒸发至干后,残渣用乙腈和水复溶。在Zorbax Eclipse Plus C18柱上进行高效液相色谱分离,采用含1mM醋酸铵的水和乙腈的梯度洗脱程序。对于牛奶中氯氰碘柳胺的测定,该方法根据欧盟第8卷指南进行验证,而对于羊奶,则同时采用欧盟第8卷和VICH GL49标准。该方法的线性范围为10至2000μg/kg,定量限为10μg/kg,羊初乳和罐装牛奶的检测限分别为0.63和0.32μg/kg,牛初乳和罐装牛奶的检测限分别为1.27和1.24μg/kg。尽管验收标准可能不同(准确度和精密度),或者两个指南均未规定具体的可接受范围(检测限和定量限),但两个指南涵盖的参数集相似(线性、准确度、精密度、检测限和定量限)。对于某些参数,只有一个指南指明了验收标准:欧盟第8卷针对适用性、实用性和敏感性,VICH GL 49针对线性、特异性和分析物稳定性。