We analysed the impact of the Xpert(®) MTB/RIF molecular test on health-care diagnostic delay among tuberculosis patients. Diagnostic delay was 17.2 days (standard deviation 23.2, median 10 days). Of 128 patients recruited into the study, 60 (47%) were smear-negative; of these, 40 (67%) were Xpert-positive and were started on treatment without culture. The sensitivity of smear microscopy was 53% compared with 82% for Xpert. In smear-negative patients, delay in Xpert-positive and -negative patients was respectively 15.5 ± 13.2 and 25.5 ± 12.5 days (P = 0.002). We conclude that Xpert results were significantly associated with shorter health-care diagnostic delay, particularly in smear-negative patients.
我们分析了Xpert(®)MTB/RIF分子检测对结核病患者医疗诊断延迟的影响。诊断延迟为17.2天(标准差23.2,中位数10天)。纳入该研究的128例患者中,60例(47%)涂片阴性;其中40例(67%)Xpert检测呈阳性,未进行培养即开始治疗。涂片显微镜检查的敏感性为53%,而Xpert为82%。在涂片阴性患者中,Xpert检测阳性和阴性患者的延迟分别为15.5±13.2天和25.5±12.5天(P = 0.002)。我们得出结论,Xpert检测结果与较短的医疗诊断延迟显著相关,尤其是在涂片阴性患者中。