Use of statistical modeling to reassess the performance standard for the AOAC use-dilution methods (955.15 and 964.02).

作者信息

Tomasino Stephen F, Parker Albert E, Hamilton Martin A

出版信息

J AOAC Int. 2014 Jan-Feb;97(1):68-77. doi: 10.5740/jaoacint.13-216.

DOI:10.5740/jaoacint.13-216
PMID:24672861
Abstract

The AOAC Use-dilution methods (UDM) 955.15 (Staphylococcus aureus) and 964.02 (Pseudomonas aeruginosa) are laboratory methods used to substantiate antimicrobial efficacy claims for liquid disinfectants on inanimate surfaces. The UDM is accepted by the U.S. Environmental Protection Agency for the purpose of product registration. To attain a hospital-level claim, testing against S. aureus and P. aeruginosa is required, and the product must pass against both microbes. Currently, the UDM's performance standard for a single 60-carrier test is the same for both microbes, and allows up to one positive carrier for the product to be considered as a pass. In this paper, the performance standards for these methods are reassessed using data from a 2009 five-laboratory collaborative study and a recently published statistical model. The reassessment focuses on the pass-error rate for ineffective products and the fail-error rate for highly effective products. The calculations indicate that the pass-error rate is between 9 and 24% and the fail-error rate between 18 and 23% when the current performance standard is used for a single test. For product registration, a smaller pass-error rate (1%) historically has been maintained by requiring that a disinfectant pass three UDM tests for each of the two microbes; however, the calculations also indicate that the fail-error rate is between 42 and 45%. This large fail-error rate is a compelling reason to consider a new performance standard for the two UDM methods, 955.15 (S. aureus) and 964.02 (P. aeruginosa). One alternative performance standard allows no more than six positive carriers out of 60 as a pass when using P. aeruginosa and no more than three positive carriers out of 60 when using S. aureus. In addition, the new performance standard requires that three UDM tests be performed with each of the two microbes, and the disinfectant must pass all six tests to be considered efficacious. The statistical calculations for this alternative performance standard indicate that the pass-error rate is no more than 3%, while the fail-error rate is as small as 5%. Based on these error rate calculations, proposed revisions to the performance standards for AOAC Methods 955.15 and 964.02 are provided.

摘要

相似文献

1
Use of statistical modeling to reassess the performance standard for the AOAC use-dilution methods (955.15 and 964.02).
J AOAC Int. 2014 Jan-Feb;97(1):68-77. doi: 10.5740/jaoacint.13-216.
2
Performance of the AOAC use-dilution method with targeted modifications: collaborative study.AOAC使用稀释法的性能及针对性修改:协作研究
J AOAC Int. 2012 Nov-Dec;95(6):1618-28. doi: 10.5740/jaoacint.12-170.
3
A statistical model for assessing performance standards for quantitative and semiquantitative disinfectant test methods.
J AOAC Int. 2014 Jan-Feb;97(1):58-67. doi: 10.5740/jaoacint.13-105.
4
Should the AOAC use-dilution method be continued for regulatory purposes?AOAC使用稀释法用于监管目的是否应继续?
J AOAC Int. 2012 Mar-Apr;95(2):406-10. doi: 10.5740/jaoacint.11-015.
5
Disinfectant testing using a modified use-dilution method: collaborative study.采用改良使用稀释法进行消毒剂测试:协作研究
J Assoc Off Anal Chem. 1988 Nov-Dec;71(6):1187-94.
6
Improving the AOAC use-dilution method by establishing a minimum log density value for test microbes on inoculated carriers.通过为接种载体上的测试微生物确定最小对数密度值来改进AOAC使用稀释法。
J AOAC Int. 2009 Sep-Oct;92(5):1531-40.
7
Ineffectiveness of hospital disinfectants against bacteria: a collaborative study.医院消毒剂对细菌的无效性:一项合作研究。
Infect Control. 1987 Dec;8(12):501-6. doi: 10.1017/s0195941700067564.
8
Modifications to the AOAC use-dilution test for quaternary ammonium compound-based disinfectants that significantly improve method reliability.对基于季铵化合物的消毒剂的AOAC使用稀释试验的修改,显著提高了方法的可靠性。
J AOAC Int. 2008 Jan-Feb;91(1):152-8.
9
Enumeration procedure for monitoring test microbe populations on inoculated carriers in AOAC use-dilution methods.美国分析化学家协会使用稀释法对接种载体上的测试微生物种群进行监测的计数程序。
J AOAC Int. 2006 Nov-Dec;89(6):1629-34.
10
Interlaboratory evaluations of a standardized quantitative test method for determining the bactericidal and tuberculocidal efficacy of antimicrobial substances on hard non-porous surfaces.用于确定抗菌物质在坚硬无孔表面上的杀菌和杀结核杆菌效力的标准化定量测试方法的实验室间评估。
J Microbiol Methods. 2022 May;196:106460. doi: 10.1016/j.mimet.2022.106460. Epub 2022 Apr 14.