Two simple and accurate methods to determine pitavastatin calcium (PIT) and ezetimibe (EZE), in a binary mixture, were developed and validated using LC and densitometric-TLC. The LC separation was achieved on a Phenomenex Luna C18 column (250 x 4.6 mm id, 5 microm), in the isocratic mode using 0.1% orthophosphoric acid-acetonitriletriethylamine (19.8 + 80 + 0.2, v/v/v), pH 3.00 +/- 0.05, at a flow rate of 1.4 mL/min. The retention times were about 6.98 and 2.36 min for PIT and EZE, respectively. Quantification was achieved with a photodiode array detector at 235 nm over the concentration range of 0.5-5 microg/mL for each drug, with mean recoveries of 99.35 +/- 0.19% and 99.51 +/- 0.23% for PIT and EZE, respectively. The TLC separation was achieved on silica gel 60 F254 HPTLC plates using toluene-ethyl acetate-glacial acetic acid (59.8 + 40.0 + 0.2, v/v/v), as the mobile phase. The R(f) values were about 0.38 and 0.58 for PIT and EZE, respectively. Quantification was achieved with UV detection at 235 nm over the concentration range of 50-600 ng/spot for each drug, with mean recoveries of 99.49 +/- 0.15% and 99.58 +/- 0.10% for PIT and EZE, respectively. Both methods were validated, and based on statistical results were found to be specific, accurate, precise, and robust. The methods were successfully applied for the determination of PIT and EZE in a binary mixture without any interferences from common excipients.

摘要

开发并验证了两种简单准确的方法,用于测定二元混合物中的匹伐他汀钙(PIT)和依折麦布(EZE),分别采用液相色谱法(LC)和薄层扫描法(densitometric - TLC)。LC分离在Phenomenex Luna C18柱(250×4.6 mm内径,5μm)上进行,等度洗脱模式下使用0.1%正磷酸 - 乙腈 - 三乙胺(19.8 + 80 + 0.2,v/v/v),pH 3.00±0.05,流速为1.4 mL/min。PIT和EZE的保留时间分别约为6.98和2.36分钟。使用光电二极管阵列检测器在235 nm处对每种药物在0.5 - 5μg/mL的浓度范围内进行定量,PIT和EZE的平均回收率分别为99.35±0.19%和99.51±0.23%。TLC分离在硅胶60 F254高效薄层板上进行,以甲苯 - 乙酸乙酯 - 冰醋酸(59.8 + 40.0 + 0.2,v/v/v)作为流动相。PIT和EZE的比移值(R(f))分别约为0.38和0.58。使用紫外检测器在235 nm处对每种药物在50 - 600 ng/斑点的浓度范围内进行定量,PIT和EZE的平均回收率分别为99.49±0.15%和99.58±0.10%。两种方法均经过验证,基于统计结果发现它们具有特异性、准确性、精密度和稳健性。这些方法成功应用于二元混合物中PIT和EZE的测定,不受常见辅料的干扰。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验