Suppr超能文献

人跟腱断裂模型中无结倒刺缝线修复的生物力学评估

Biomechanical evaluation of a knotless barbed suture repair in a human Achilles tendon rupture model.

作者信息

Kanz Brian N, Morris Randal P, Lewis Taylor, Panchbhavi Vinod K

机构信息

CHRISTUS Santa Rosa Medical Group, Westover Hills Orthopaedics, San Antonio, Texas (BNK).

出版信息

Foot Ankle Spec. 2014 Jun;7(3):176-81. doi: 10.1177/1938640014528041. Epub 2014 Mar 30.

Abstract

BACKGROUND

Knotless barbed sutures are seeing more common use in wound closures and small tendon repairs. The purpose of this study was to evaluate the strength and resistance to gap formation of these sutures in larger tendons, such as the Achilles, compared with conventional repair.

METHODS

Six matched pairs of fresh-frozen human cadaver Achilles tendons were transected to simulate a rupture. Six tendons were repaired using a double Bunnell over-the-top technique with Fiberwire, and the matched pairs were repaired using a double Bunnell knotless technique with barbed suture. The tendons were tested to failure and stiffness, peak failure load, percentage elongation, load at initial gap and load at 5-mm gap (clinical failure) were compared.

RESULTS

The mean peak failure load for the Fiberwire group (459 N) was significantly higher (P = .029) compared with the barbed suture group (184 N). Percentage elongation at peak load was significantly lower in the barbed suture group (P = .014), as was percentage elongation at initial gapping (P = .007) and percent elongation at 5 mm of gapping (P = .004).

CONCLUSION

While the knotless barbed suture is attractive for its design and resistance to gap formation, low failure loads compared with conventional suture are concerning for large tendon repairs.

LEVELS OF EVIDENCE

Therapeutic, Level IV: Bench testing.

摘要

背景

无结倒刺缝线在伤口闭合和小肌腱修复中的应用越来越普遍。本研究的目的是评估与传统修复相比,这些缝线在较大肌腱(如跟腱)中的强度和抗间隙形成能力。

方法

将六对新鲜冷冻的人类尸体跟腱切断以模拟断裂。六根肌腱采用双Bunnell经顶技术用Fiberwire修复,配对的肌腱采用双Bunnell无结技术用倒刺缝线修复。对肌腱进行破坏试验,并比较其刚度、峰值破坏载荷、伸长百分比、初始间隙时的载荷和5毫米间隙(临床失败)时的载荷。

结果

Fiberwire组的平均峰值破坏载荷(459 N)显著高于倒刺缝线组(184 N)(P = .029)。倒刺缝线组在峰值载荷时的伸长百分比显著较低(P = .014),初始间隙时的伸长百分比(P = .007)和5毫米间隙时的伸长百分比(P = .004)也较低。

结论

虽然无结倒刺缝线因其设计和抗间隙形成能力而具有吸引力,但与传统缝线相比,其低破坏载荷对于大肌腱修复而言令人担忧。

证据水平

治疗性,IV级:实验室测试。