动脉导管未闭封堵术中并发下腔静脉假性中断:病例报告及静脉系统胚胎学简要回顾

Pseudo interruption of the inferior vena cava complicating the device closure of patent ductus arteriosus: Case report and short review of venous system embryology.

作者信息

Subramanian Venkateshwaran, Mahadevan Krishnamoorthy Kavassery, Sivasubramonian Sivasankaran, Tharakan Jaganmohan

机构信息

Department of Cardiology, Sreechitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala, India.

出版信息

Ann Pediatr Cardiol. 2014 Jan;7(1):64-6. doi: 10.4103/0974-2069.126567.

Abstract

A nineteen-month-old girl was taken up for patent ductus arteriosus (PDA) device closure. A diagnostic catheter from the right femoral venous access entered the superior vena cava (SVC), through the azygos vein suggesting interruption of inferior vena caval with azygos continuity. Therefore, the PDA device was closed from the right jugular venous access. However, a postprocedure echocardiogram (echo) showed a patent inferior vena caval connection into the right atrium. An angiogram from femoral veins showed communication between the iliac veins and the azygos system, in addition to normal drainage into the inferior vena cava (IVC). Congenital communication between the iliac veins and the azygos system can mimic IVC interruption. An attempt to theoretically explain the embryological origin of the communication has been made.

摘要

一名19个月大的女童因动脉导管未闭(PDA)接受封堵术。一根诊断导管经右股静脉进入上腔静脉(SVC),通过奇静脉,提示下腔静脉中断伴奇静脉连续性。因此,经右颈静脉途径封堵PDA装置。然而,术后超声心动图(echo)显示下腔静脉与右心房之间存在未闭连接。股静脉造影显示髂静脉与奇静脉系统之间存在交通,此外还有正常的下腔静脉(IVC)引流。髂静脉与奇静脉系统之间的先天性交通可模拟IVC中断。本文尝试从理论上解释这种交通的胚胎学起源。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3997/3959068/5322a1acadb3/APC-7-64-g001.jpg

相似文献

2
Device closure of patent ductus arteriosus in interrupted inferior vena cava.
Indian Heart J. 2015 Dec;67 Suppl 3(Suppl 3):S85-7. doi: 10.1016/j.ihj.2015.09.015. Epub 2016 Jan 18.
3
Congenital systemic venous return anomalies to the right atrium review.
Insights Imaging. 2019 Dec 4;10(1):115. doi: 10.1186/s13244-019-0802-y.
9
Transcatheter closure of a large patent ductus arteriosus using jugular access in an infant.
J Thorac Dis. 2018 Mar;10(3):E207-E209. doi: 10.21037/jtd.2018.02.54.
10
Patent Ductus Arteriosus Device Closure in Interrupted Inferior Vena Cava: Challenges Overcome and Lessons Learnt: A Case Series.
Heart Views. 2021 Jan-Mar;22(1):71-75. doi: 10.4103/HEARTVIEWS.HEARTVIEWS_180_20. Epub 2021 Apr 22.

引用本文的文献

1
Intervention Challenges in Patients with Congenital Heart Disease with Coexisting Interruption of the Inferior Vena Cava - A Case Series.
Heart Views. 2021 Jul-Sep;22(3):224-230. doi: 10.4103/HEARTVIEWS.HEARTVIEWS_197_20. Epub 2021 Oct 11.
2
Patent Ductus Arteriosus Device Closure in Interrupted Inferior Vena Cava: Challenges Overcome and Lessons Learnt: A Case Series.
Heart Views. 2021 Jan-Mar;22(1):71-75. doi: 10.4103/HEARTVIEWS.HEARTVIEWS_180_20. Epub 2021 Apr 22.
3
Transcatheter closure of a large patent ductus arteriosus using jugular access in an infant.
J Thorac Dis. 2018 Mar;10(3):E207-E209. doi: 10.21037/jtd.2018.02.54.
4
Device closure of patent ductus arteriosus in interrupted inferior vena cava.
Indian Heart J. 2015 Dec;67 Suppl 3(Suppl 3):S85-7. doi: 10.1016/j.ihj.2015.09.015. Epub 2016 Jan 18.

本文引用的文献

1
Congenital anomalies of the venae cavae: embryological origin, imaging features and report of three new variants.
Eur Radiol. 2002 Aug;12(8):2040-55. doi: 10.1007/s00330-001-1241-x. Epub 2002 Mar 19.
2
Spectrum of congenital anomalies of the inferior vena cava: cross-sectional imaging findings.
Radiographics. 2000 May-Jun;20(3):639-52. doi: 10.1148/radiographics.20.3.g00ma09639.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验