Suppr超能文献

用于评估骨关节炎中髌骨高度的髌骨平台角

Plateau-patella angle in evaluation of patellar height in osteoarthritis.

作者信息

Ellington Matthew, Robin Brett, Jupiter Daniel, Allen Bryce

机构信息

Scott & White Healthcare, Temple, TX, United States.

Scott & White Healthcare, Temple, TX, United States.

出版信息

Knee. 2014 Jun;21(3):699-702. doi: 10.1016/j.knee.2014.02.026. Epub 2014 Mar 20.

Abstract

BACKGROUND

The plateau-patella angle (PPA), recently introduced as a new and simpler method of measuring patellar height from the lateral radiograph, has the advantage of simplicity over previously described methods as it involves a single angular measurement without the need for calculations. The purpose of this study was to validate the use of the PPA as a measurement for patellar height in knees with moderate to severe osteoarthritis.

METHODS

A total of 331 patients who underwent total knee arthroplasty at our institution with radiographs prior to surgery were evaluated. Of those, 297 (89.2%) were felt to be adequate for review. Three observers with different levels of orthopedic training measured PPA, Insall-Salvati, Caton-Deschamps, and Blackburne-Peel indices on a subset of 50 consecutive patients. Interobserver agreement for each of the four measurements was calculated and correlation between each of the measurements within each observer was calculated. The measurement of the PPA was repeated. Intraobserver agreement for the PPA was determined and a normal range and distribution was defined for this population.

RESULTS

For the three observers, the mean PPA for the entire cohort was 25.55, 25.31, and 24.42. The intraclass correlation coefficient (ICC) was 0.81, The ICC and intraobserver assessment were the highest for the PPA compared with the other ratios. The PPA was found to correlate most strongly with the Blackburne-Peel method.

CONCLUSIONS

The plateau-patella angle is a reliable way to evaluate patellar height in the osteoarthritic population. The measurement demonstrated a higher interobserver reliability compared with previously described methods.

LEVEL OF EVIDENCE

Retrospective Level IV.

摘要

背景

高原-髌骨角(PPA)是最近提出的一种从膝关节侧位X线片测量髌骨高度的新的、更简单的方法,与先前描述的方法相比,它具有简单的优点,因为它只涉及单一角度测量,无需计算。本研究的目的是验证PPA作为中度至重度骨关节炎膝关节髌骨高度测量方法的有效性。

方法

对在我院接受全膝关节置换术且术前有X线片的331例患者进行评估。其中,297例(89.2%)被认为适合进行回顾性分析。三名接受不同程度骨科培训的观察者对连续50例患者的子集测量了PPA、Insall-Salvati、Caton-Deschamps和Blackburne-Peel指数。计算了四名观察者对每项测量的观察者间一致性,并计算了每位观察者内每项测量之间的相关性。重复测量PPA。确定了PPA的观察者内一致性,并为该人群定义了正常范围和分布。

结果

对于三名观察者,整个队列的平均PPA分别为25.55、25.31和24.42。组内相关系数(ICC)为0.81,与其他比率相比,PPA的ICC和观察者内评估最高。发现PPA与Blackburne-Peel方法的相关性最强。

结论

高原-髌骨角是评估骨关节炎患者髌骨高度的可靠方法。与先前描述的方法相比,该测量方法显示出更高的观察者间可靠性。

证据水平

回顾性IV级。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验