The study aims to establish a quantitative nuclear magnetic resonance (QNMR) method for the determination of the absolute content of bosentan. Proton nuclear magnetic resonance spectroscopy [1H NMR] spectra were obtained in CDCl3 with the internal standard dimethyl terephthalate and zg30 pulse sequence by using a Bruker AVANCE II 400 spectrometer. The content of bosentan is determined with QNMR in comparison with the result obtained by mass balance method. The result is 96.25% by QNMR and 96.54% by mass balance method. A rapid and accurate QNMR method has been established for the quantitative determination of the absolute content of bosentan. The study provides a new way for the quality control and calibration of a new reference standard material, it could be the complementary with the mass balance method for the assay of standard reference.
本研究旨在建立一种用于测定波生坦绝对含量的定量核磁共振(QNMR)方法。使用布鲁克AVANCE II 400型光谱仪,以对苯二甲酸二甲酯为内标,采用zg30脉冲序列,在CDCl3中获得质子核磁共振波谱[1H NMR]。通过QNMR测定波生坦的含量,并与质量平衡法所得结果进行比较。QNMR法测定结果为96.25%,质量平衡法测定结果为96.54%。已建立了一种快速准确的QNMR方法用于定量测定波生坦的绝对含量。该研究为新参考标准物质的质量控制和校准提供了一种新方法,可作为标准参考物测定中质量平衡法的补充。