Flanigan David C, Harris Joshua D, Jia Guang, Choi Seongjin, Siston Robert A, Randazzo John L, Knopp Michael
Orthopedics. 2014 Apr;37(4):e322-7. doi: 10.3928/01477447-20140401-50.
The purpose of this study was to determine the sensitivity and positive predictive value of magnetic resonance imaging (MRI) in the identification of full-thickness articular cartilage defects in the porcine knee. Seventy-two full-thickness chondral defects (small or large; circular, oval, or triangular) were created in 12 porcine knees. The authors used 3.0-T MRI with 3-dimensional gradient echo water-selective/fluid (WATSf) sequences acquired in axial, coronal, and sagittal planes. Sensitivity and positive predictive value parameters were calculated for 2 readers. Magnetic resonance imaging was highly sensitive for detection of full-thickness defects in the knee (85%). The highest sensitivity was observed at the medial femoral condyle (93%), while the lowest was observed at the medial patella (71%). The sensitivities for detecting different shapes were unique to each shape, with oval lesions identified with greatest sensitivity (93%). Small lesions (86%) were detected at a similar sensitivity as large lesions (83%). The positive predictive values for accurate true-positive reads were low for all lesion shapes (18%-57%) and moderate for small (69%) and large (59%) sizes, with significant differences observed between the 2 readers. Magnetic resonance imaging has a high sensitivity in the detection of full-thickness articular cartilage defects in the porcine knee. Variability in defect shape and intra-articular location affects MRI sensitivity, while size does not. Magnetic resonance imaging was not effective in describing lesion shape or size. Further, there was subjectivity in reading defect shape and size between 2 radiologists.
本研究的目的是确定磁共振成像(MRI)在识别猪膝关节全层关节软骨缺损方面的敏感性和阳性预测值。在12个猪膝关节中制造了72个全层软骨缺损(小或大;圆形、椭圆形或三角形)。作者使用3.0-T MRI,通过在轴向、冠状面和矢状面获取的三维梯度回波水选择性/流体(WATSf)序列进行检查。计算了2名阅片者的敏感性和阳性预测值参数。磁共振成像对膝关节全层缺损的检测具有高度敏感性(85%)。在内侧股骨髁观察到最高敏感性(93%),而在内侧髌骨观察到最低敏感性(71%)。检测不同形状缺损的敏感性因形状而异,椭圆形病变的识别敏感性最高(93%)。小病变(86%)的检测敏感性与大病变(83%)相似。所有病变形状的准确真阳性阅片的阳性预测值都较低(18%-57%),小尺寸病变(69%)和大尺寸病变(59%)的阳性预测值为中等,2名阅片者之间存在显著差异。磁共振成像在检测猪膝关节全层关节软骨缺损方面具有较高的敏感性。缺损形状和关节内位置的变异性会影响MRI敏感性,而尺寸则不会。磁共振成像在描述病变形状或大小方面效果不佳。此外,两名放射科医生在读取缺损形状和大小方面存在主观性。