Suppr超能文献

黑白人种患者使用 Ex-PRESS 青光眼引流阀的长期比较。

Long-term comparison using Ex-PRESS glaucoma shunt in black and white patients.

机构信息

Department of Ophthalmology, State University of New York, Downstate Medical Center, Brooklyn, N.Y..

Department of Ophthalmology, State University of New York, Downstate Medical Center, Brooklyn, N.Y.

出版信息

Can J Ophthalmol. 2014 Apr;49(2):200-4. doi: 10.1016/j.jcjo.2013.09.021.

Abstract

OBJECTIVE

To compare clinical outcomes, including patterns of failure, using the Ex-PRESS glaucoma shunt, in black and white patients with open-angle glaucoma.

DESIGN

Retrospective comparative study.

PARTICIPANTS

Sixty-three eyes of 50 black patients and 44 eyes of 34 white patients with open-angle glaucoma.

METHODS

The Ex-PRESS shunt procedure was performed for uncontrolled glaucoma in a series of white and black patients with glaucoma. Success was defined as an intraocular pressure (IOP) between 5 and 18 mm Hg, 20% reduction from baseline, with or without suture lysis or adjuvant medication, but no additional glaucoma surgery.

RESULTS

Mean length of follow-up was 29 months (range 12-81 months) for black patients and 25 months (range 12-66 months) for white patients. Mean preoperative IOP was 27 ± 7.2 and 30 ± 7.7 mm Hg for black and white patients, respectively. Mean postoperative IOP was 13 ± 3.6 and 12 ± 3.3 mm Hg for black and white patients, respectively. Using Kaplan-Meier survival curves, the success rates were 77.6% and 95% at 12 months for black and white patients, respectively. The log-rank test for comparison of survival curves indicated a significant difference between the 2 groups at 12 months (p = 0 .015) but revealed no difference at 2 years (p = 0.462).

CONCLUSIONS

This study shows that patterns of failure between black and white patients treated with the Ex-PRESS glaucoma shunt change significantly with the passage of time. Black patients experience failure early, whereas white patients experience failure later at a greater pace resulting in a similar survival rate at 2 years.

摘要

目的

比较 Ex-PRESS 青光眼引流器在黑人及白人开角型青光眼患者中的临床效果,包括失败模式。

设计

回顾性比较研究。

参与者

50 例黑人患者的 63 只眼和 34 例白人患者的 44 只眼均患有开角型青光眼。

方法

对一系列黑人及白人青光眼患者施行 Ex-PRESS 引流器手术,治疗控制不良的青光眼。成功定义为眼压(IOP)在 5 至 18mmHg 之间,较基线值降低 20%,无需缝线松解或辅助药物治疗,但无需进一步行青光眼手术。

结果

黑人患者的平均随访时间为 29 个月(12-81 个月),白人患者为 25 个月(12-66 个月)。黑人及白人患者术前平均 IOP 分别为 27 ± 7.2mmHg 和 30 ± 7.7mmHg。黑人及白人患者术后平均 IOP 分别为 13 ± 3.6mmHg 和 12 ± 3.3mmHg。Kaplan-Meier 生存曲线显示,黑人及白人患者的 12 个月成功率分别为 77.6%和 95%。两组患者生存曲线的对数秩检验显示,12 个月时两组间差异有统计学意义(p = 0.015),但 2 年时差异无统计学意义(p = 0.462)。

结论

本研究表明,黑人及白人患者接受 Ex-PRESS 青光眼引流器治疗后的失败模式随时间推移显著改变。黑人患者早期失败,而白人患者后期失败速度更快,导致 2 年时的生存率相似。