[Research on spectral characteristic of miniature X-ray tube and determination of beryllium window thickness].

作者信息

Gu Yi, Xiong Sheng-Qing, Ge Liang-Quan, Fan Zheng-Guo, Zhang Qing-Xian, Zhu Zhen-Ya

出版信息

Guang Pu Xue Yu Guang Pu Fen Xi. 2014 Jan;34(1):252-6.

PMID:24783571
Abstract

Applying Monte Carlo method, the present paper simulates the emitted X-ray spectrum of miniature X-ray tube with thirteen thickness of beryllium window in the range from 50 to 500 microm. By analyzing the characteristic of the spectrums, the reasonable choice of thickness of beryllium window relies on the application and for the beryllium window it is not the thinner the better. Taking in-situ EDXRF as an example, though the emission X-ray intensity is higher as the thickness of the beryllium window becomes thinner, the proportion of useless low-energy X-ray (<5 keV) intensity to all energy X-ray intensity also is higher (>20%). The accuracy of in-situ EDXRF will be reduced when the high-throughput low-energy X-ray enters the detector. Therefore, this paper puts forward several parameters as judgment index for beryllium window thickness, which is described as follows: 1)The intensity ratios of the K-series X-ray to middle-energy (5-25 keV) bremsstrahlung and middle-high-energy (5-50 keV) bremsstrahlung (F1 and F3); 2)The intensity ratios of useless low-energy X-ray (<5 keV) to middle-energy (5-25 keV) X-ray and middle-high-energy (5-50 keV) X-ray (F2 and F4), it can reflect the relative intensity of useless low-energy X-ray. The simulation results demonstrate that with the increase in the beryllium window thickness, the value of F1 (F3) improves slowly, and the value of F2 (F4) decreases rapidly. In addition to the judgment index discussed above, and considering the X-ray shielded by beryllium window, the beryllium window of miniature X-ray tube can be determined. Based on simulation analysis, the thickness of around 250 microm is appropriate to miniature X-ray tube applied in the in-situ EDXRF. Comparing the emitted spectrum with 50 microm-thick beryllium window, 71.66% of low-energy X-rays are shielded, only 21.31% of X-rays with energy from 5 to 50 keV is shielded, the intensity ratio of low-energy X-ray to total energy X-ray is less than 10%, and the intensity proportion of K-series X-ray to middle-high energy X-ray maintains a high level. In other words, when the mobile X-ray source with 250 microm beryllium window is used in the in-situ EDXRF, proportion of effective signal is higher, and effect of energy resolution of the detection is least; Moreover, the relative intensity of the excitation spectral scattering background, which is obtained by detection for specimen excitation analysis, will remain at low level, thus to ensure the precision of the result of element analysis. For the beryllium window in the application of radiation therapy, the thicker the better. At this time, low-energy X-ray flux maintains a high level, and it can ensure that radiation dose is concentrated on treatment tissue.

摘要

相似文献

1
[Research on spectral characteristic of miniature X-ray tube and determination of beryllium window thickness].
Guang Pu Xue Yu Guang Pu Fen Xi. 2014 Jan;34(1):252-6.
2
[Analyse Output Specurum in Miniature Transmission X-Ray Tube of Aluminum Window and Silver Target by MC Simulation].[基于蒙特卡洛模拟分析铝窗银靶微型透射X射线管的输出谱]
Guang Pu Xue Yu Guang Pu Fen Xi. 2015 Oct;35(10):2891-4.
3
[Study on the effect of target thickness on output spectrum in transmission anode micro X-ray tube by MC method].[蒙特卡洛方法研究透射式阳极微焦点X射线管靶厚度对输出能谱的影响]
Guang Pu Xue Yu Guang Pu Fen Xi. 2013 Aug;33(8):2231-4.
4
[Theoretical calculation and simulation research on micro X-ray tube target thickness and spectra].
Guang Pu Xue Yu Guang Pu Fen Xi. 2013 Apr;33(4):1130-4.
5
Dual energy-band excitation from a low power Rh anode X-ray tube for the simultaneous determination of low Z and high Z elements (Na-U) using total-reflection X-ray fluorescence analysis (TXRF).利用全反射X射线荧光分析(TXRF),通过低功率铑阳极X射线管进行双能带激发,同时测定低Z和高Z元素(钠-铀)。
Rev Sci Instrum. 2018 Sep;89(9):093108. doi: 10.1063/1.5044527.
6
Image noise in X-ray imaging caused by radiation scattering and source leakage, a qualitative and quantitative analysis.X 射线成像中的辐射散射和源泄漏引起的图像噪声:定性和定量分析。
J Xray Sci Technol. 1998 Jan 1;8(1):19-29.
7
[Low energy tail spectra of characteristic X-rays detected by a Si(Li) X-ray detector].[硅(锂)X射线探测器检测到的特征X射线的低能尾谱]
Radioisotopes. 1984 Mar;33(3):119-24.
8
Application of MLP neural network to predict X-ray spectrum from tube voltage, filter material, and filter thickness used in medical imaging systems.将多层感知机神经网络应用于预测医学成像系统中使用的管电压、滤光材料和滤光片厚度的 X 射线光谱。
PLoS One. 2023 Dec 7;18(12):e0294080. doi: 10.1371/journal.pone.0294080. eCollection 2023.
9
Therapeutic dose from a pyroelectric electron accelerator.
Radiat Res. 2009 Nov;172(5):643-7. doi: 10.1667/RR1876.1.
10
Fast and simple method for determination of fatty acid methyl esters (FAME) in biodiesel blends using X-ray spectrometry.利用 X 射线光谱法快速简单地测定生物柴油混合物中的脂肪酸甲酯(FAME)。
Talanta. 2011 Sep 30;85(4):2000-6. doi: 10.1016/j.talanta.2011.07.046. Epub 2011 Jul 19.