Piazza Michele, Lupia Mario, Grego Franco, Antonello Michele
Vascular and Endovascular Surgery Clinic, Padova University School of Medicine, Padova, Italy
Echocardiography Service Clinic of Cardiology, Padova University School of Medicine, Padova, Italy.
Vascular. 2015 Apr;23(2):161-4. doi: 10.1177/1708538114533538. Epub 2014 May 6.
The technique is demonstrated in a 78-year-old man; the preoperative CT angiogram showed a descending thoracic aorta ulcer of 5.9 cm in maximum diameter and 3.8 cm longitudinal extension. A ZTEG-2P-36-127-PF (Cook Medical) single tubular endograft was planned to be deployed. From the preoperative CT angiogram we planned to land 4.7 cm above the midline of the descending thoracic aorta ulcer and 8.0 cm below. In the operating room, under radioscopic vision the centre of the transesophageal echography probe was used as marker to identify the correspondent midline of the descending thoracic aorta ulcer and a centimeter-sized pigtail catheter in the aorta was used to calculate the desired length above and below the ulcer midline. The endograft was introduced and placed in the desired position compared to the transesophageal echography probe and the catheter; under transesophageal echography vision the graft was finally deployed. The CT angiogram at 1 month showed the correct endograft position, descending thoracic aorta ulcer exclusion with no signs of endoleak. In selected cases, this method allows planning in advance safe stent graft positioning and deployment totally assisted by transesophageal echography, with no risk of periprocedural contrast-related renal failure and reduced radiation exposure for the patient and operators.
该技术在一名78岁男性患者中得到展示;术前CT血管造影显示降主动脉溃疡,最大直径5.9厘米,纵向延伸3.8厘米。计划植入一枚ZTEG-2P-36-127-PF(库克医疗公司)单管型腔内移植物。根据术前CT血管造影,我们计划将移植物放置在降主动脉溃疡中线以上4.7厘米和以下8.0厘米处。在手术室中,在X线透视下,将经食管超声探头的中心用作标记来确定降主动脉溃疡的相应中线,并使用主动脉内的厘米级猪尾导管来计算溃疡中线上下所需的长度。将腔内移植物与经食管超声探头和导管相比,引入并放置在所需位置;在经食管超声视野下,最终展开移植物。术后1个月的CT血管造影显示腔内移植物位置正确,降主动脉溃疡被排除,无内漏迹象。在选定的病例中,这种方法可以在经食管超声完全辅助下提前规划安全的支架移植物定位和展开,没有围手术期造影剂相关肾衰竭的风险,并且减少了患者和操作人员的辐射暴露。