Int J Oral Maxillofac Implants. 2014 May-Jun;29(3):550-7. doi: 10.11607/jomi.3069.
Because the maxilla and its alveolar process are prone to resorption after tooth loss, it is often necessary to perform a bone augmentation procedure to successfully carry out implant treatment in that region. The aim of this study was to determine the adhesive force between the sinus membrane and the osseous sinus floor that occurs during sinus floor elevation with a balloon lift system.
Twenty-two ex vivo pig heads were used for this study. Access to the maxillary sinus was gained via the lateral sinus wall. Sinus elevation was performed using an inflatable balloon, which was consecutively filled with 3 mL of a radiopaque fluid. Pressure was monitored directly and continuously during the elevation procedure with an electronic pressure gauge. The integrity of the membrane was checked microscopically and macroscopically.
The average adhesion force of the sinus membrane was found to be 748 ± 65.56 mmHg. On microscopic and macroscopic inspection, no mucosal tearing occurred during sinus floor elevation. Underwood septa, when present, did not significantly influence the adhesion forces.
The balloon system allowed for reproducible real-time measurement of the elevation forces and soft tissue resilience of the sinus membrane during the elevation process in this animal model. No mucosal ruptures were caused with this technical setup, in which effective elevation pressure ranging from 660 to 880 mmHg was not exceeded. A possible transfer of this technical setup to clinical procedures in humans requires investigation.
由于上颌骨及其牙槽骨在牙齿缺失后容易吸收,因此通常需要进行骨增量手术,才能在该区域成功进行种植治疗。本研究旨在确定使用球囊提升系统进行鼻窦底提升时鼻窦膜与骨性鼻窦底之间的黏附力。
本研究使用了 22 个离体猪头。通过外侧窦壁进入上颌窦。使用可充气的球囊进行鼻窦提升,球囊随后连续注入 3 毫升不透射线的液体。在提升过程中,使用电子压力计直接和连续监测压力。使用显微镜和宏观检查检查膜的完整性。
发现鼻窦膜的平均黏附力为 748 ± 65.56mmHg。在进行鼻窦底提升时,显微镜和宏观检查均未发现黏膜撕裂。如果存在 Underwood 隔,则不会显著影响黏附力。
在这个动物模型中,球囊系统允许在提升过程中实时、可重复地测量提升力和鼻窦膜的软组织弹性。在不超过 660 至 880mmHg 的有效提升压力的情况下,该技术设置不会造成黏膜破裂。将这种技术设置转移到人体的临床操作中需要进一步研究。